FEM-Parameterized PMSM

Permanent magnet synchronous motor defined in terms of magnetic flux linkage

  • FEM-Parameterized PMSM block

Libraries:
Simscape / Electrical / Electromechanical / Permanent Magnet

Description

The FEM-Parameterized PMSM block models a permanent magnet synchronous motor (PMSM) defined in terms of magnetic flux linkage. Use this block to model any three-phase machine that has a permanent magnet rotor including:

  • Axial flux (pancake) motors.

  • Brushless servomotors.

  • Motors with interior magnet rotors such as the interior permanent magnet (IPM) motor or interior permanent magnet synchronous machine (IPMSM).

  • Motors with surface-mounted magnet rotors:

    • Surface permanent magnet (SPM) motors or surface permanent magnet synchronous machines (SPMSMs).

    • Brushless DC (BLDC) motors.

You parameterize the block by providing tabulated data of the motor magnetic flux as a function of current and rotor angle. This is the way that finite element method (FEM) packages usually export flux information. Because of the tabulated form, the flux can vary nonlinearly with both rotor angle and current. The nonlinear dependence on rotor angle enables the block to support trapezoidal flux profiles exhibited by brushless DC motors and also capture the higher harmonics for motors with only approximately sinusoidal flux profiles.

This figure shows the equivalent circuit for a wye-connected PMSM. The rotor angle is zero when the permanent magnet flux aligns with the A-phase magnetic axis.

In practice, the flux linking each of the three windings depends on all three currents and rotor angle. Tabulating flux as a function of four independent variables might lead to simulation inefficiency and significant memory requirements to manage the data. The block, therefore, lets you select between the following parameterization methods for flux and torque:

  • 2-D partial derivative data — 2-D table lookup, with options to tabulate in terms of current and rotor angle, or in terms of d-axis and q-axis currents. The first option assumes constant mutual inductance and supports nonsinusoidal back emf profiles. The second option assumes a sinusoidal back emf and captures saturation effects for interior PMSMs (IPMSMs).

  • 3-D partial derivative data — 3-D table lookup, based on direct current, quadrature current, and rotor angle. You provide the flux lookup data for the a phase. The block uses Park transform to map the three stator winding currents to direct and quadrature currents. This method reduces the data complexity, as compared to the 4-D table lookup, and therefore results in improved simulation performance.

  • 4-D partial derivative data — 4-D table lookup, based on the three stator winding currents and the rotor angle. You provide the flux lookup data for the a phase. This model has the best fidelity of the three, but also is the most costly in terms of simulation performance and memory requirements.

  • 3-D flux linkage data — 3-D table lookup, based on the flux linkage data. You can provide the flux linkage data in a variety of formats. The block uses Park transform to map the three stator winding currents to direct and quadrature currents. This method reduces the data complexity, as compared to the 4-D table lookup, and therefore results in improved simulation performance.

By default, the blocks implements a wye-wound configuration for the stator windings for all these parameterizations. However, you can switch to a delta-wound or an open-end configuration by using the Winding type parameter. When in the delta-wound configuration, the a phase is connected between ports a and b, the b phase between ports b and c and the c phase between ports c and a.

To access these parameterization methods, double-click the block in your model and set the Modeling option parameter to the desired option, with or without thermal ports. By default, the thermal ports are not exposed. For more information, see Model Thermal Effects.

Note

Simscape™ Electrical™ includes several blocks that can model the same type of motor or actuator. You must choose a block that has sufficient modeling detail for the engineering design questions that you need to answer. However, do not use more detail than you need, because higher-fidelity models slow down simulation and are more complex to parameterize.

Blocks like the FEM-Parameterized PMSM block define motor behavior in terms of flux linkage. These models have a high level of fidelity. Use this block only when you need a high level of modeling detail, for example, to predict efficiency for traction applications or to capture torque and electrical current harmonics. For more information about choosing the right block to model your motor at the right level of fidelity, see Choose Blocks to Model Motors or Actuators.

2-D Data Model with Constant Mutual Inductance

In this 2-D flux data model, the flux linking each winding is assumed to depend nonlinearly only on the current in that same winding, plus the rotor angle. In practice, this is a reasonable assumption for many permanent magnet synchronous motors; however, it is less accurate for switched reluctance motors. Given this assumption, the fluxes in the three windings are:

[ϕaϕbϕc]=[0MsMsMs0MsMsMs0][iaibic]+[ϕ(ia,θr)ϕ(ib,θr2π/(3N))ϕ(ic,θr4π/(3N))]

where ϕ(θr,ia) is the flux linkage for the A-phase winding as a function of rotor angle and A-phase current. Θr = 0 corresponds to the rotor d-axis aligning with the A-phase positive magnetic flux direction. Ms is the stator-stator mutual inductance.

For improved numerical performance, the equations implemented in the block actually work with the partial derivatives of flux linkage with respect to current, ϕ(i,θr)/i, and rotor angle, ϕ(i,θr)/θr, rather than the flux directly. If your FEM package does not export these partial derivatives, you can determine them using a MATLAB® script. See the Solenoid Parameterized with FEM Data example model and its supporting MATLAB script for an example of how to do this.

The electrical equations for the block, defined in terms of flux partial derivatives, are:

va=ϕiadiadt+ϕθrdθrdtMs(dibdt+dicdt)+Rsiavb=ϕibdibdt+ϕθrdθrdtMs(diadt+dicdt)+Rsibvc=ϕicdicdt+ϕθrdθrdtMs(diadt+dibdt)+Rsic

where

  • va, vb, vc are the voltages applied to the A, B, and C stator windings.

  • ia, ib, ic are the stator currents in each of the three windings.

  • Rs is the resistance of each of the stator windings.

  • Ms is the stator-stator mutual inductance.

  • ϕ/ia, ϕ/ibϕ/ic are the partial derivatives of flux linkage with respect to stator current in each of the three windings.

  • ϕ/θr is the partial derivative of flux linkage with respect to rotor angle.

The block can automatically calculate the torque matrix from the flux information that you provide. Alternatively, you can set the Calculate torque matrix? parameter to No and directly specify the torque as a function of current and rotor angle. See the FEM-Parameterized Rotary Actuator block reference page for more information.

2-D Data Model with Sinusoidal Back EMF

In this 2-D flux data model, the flux linking each winding is assumed to depend nonlinearly on all stator winding currents, plus it is assumed that the permanent magnet flux linkage is sinusoidal. Interior magnet PMSMs (or IPMSMs) usually fit this assumption well. The equations are:

[ϕdϕq]=[Ld(id,iq)Lq(id,iq)][idiq]+[ϕm(id,iq)]

T=32N(iq(idLd(id,iq)+ϕm(id,iq))idiqLq(id,iq))

where

  • id and iq are the d-axis and q-axis currents, respectively.

  • ϕd and ϕq are the d-axis and q-axis flux linkages, respectively.

  • ϕm is the permanent magnet flux linkage.

  • Ld and Lq are the d-axis and q-axis inductances, respectively. They are assumed to depend on the d-axis and q-axis currents.

  • N is the number of pole pairs.

  • T is the electrical torque.

3-D Partial Derivative Data Model Using Park Transform

Working with four-dimensional data has both a simulation performance cost and a memory cost. To reduce the table dimension to three-dimensional, the 3-D data model uses Park transform to map the three currents to direct and quadrature currents:

[idiq]=23[cos(Nθr)cos(Nθr2π3)cos(Nθr+2π3)sin(Nθr)sin(Nθr2π3)sin(Nθr+2π3)][iaibic]

In the general case, Park transform maps to direct, quadrature, and zero-sequence currents. However, the zero-sequence current is typically small under normal operating conditions. Therefore, the model neglects the dependence of the flux linkage terms on zero-sequence current, and determines the flux linkage in terms of just direct and quadrature currents plus rotor angle. The flux equation for the 3-D data model is:

[ϕaϕbϕc]=[ϕ(id,iq,θr)ϕ(id,iq,θr2π/(3N))ϕ(id,iq,θr4π/(3N))]

The electrical equations for the block are also defined in terms of flux partial derivatives, similar to the 4-D data model. You can calculate 3-D flux linkage partial derivative data from 4-D flux linkage data using ee_calculateFluxPartialDerivatives.

4-D Partial Derivative Data Model

The flux linking each of the windings is a function of the current in that winding, the currents in the other two windings, and the rotor angle. For full accuracy, the 4-D flux data model assumes that the flux linkage is a function of the three currents and the rotor angle, therefore performing four-dimensional table lookups. The flux equation is:

[ϕaϕbϕc]=[ϕ(ia,ib,ic,θr)ϕ(ib,ic,ia,θr2π/(3N))ϕ(ic,ia,ib,θr4π/(3N))]

where

  • ϕa, ϕb, ϕc are the flux linkages for the A, B, and C stator windings.

  • ia, ib, ic are the stator currents in each of the three windings.

  • Θr is the rotor angle. Θr = 0 corresponds to the case where the permanent magnet flux is aligned with the A-phase stator winding flux.

  • N is the number of pole pairs.

Flux linkage data is assumed cyclic with Θr. If, for example, the motor has six pole pairs, then the range for the data is 0 ≤ Θr ≤ 60°. You must provide data both at 0 and 60 degrees, and because the data is cyclic, the flux linkage partial derivatives must be the same at these two end points.

The torque equation is:

τ=T(ia,ib,ic,θr)

The 4-D data model does not have an option for the block to determine torque from flux linkage. Because of the increased numerical overhead in the 4-D case, it is better to precalculate the torque just once, rather than calculate it every time you run the simulation.

For improved numerical performance, the equations implemented in the block actually work with the partial derivatives of flux linkage with respect to the three currents and the rotor angle, rather than the flux directly. If your FEM package does not export these partial derivatives, you can determine them using ee_calculateFluxPartialDerivatives.

The electrical equations for the block, defined in terms of flux partial derivatives, are:

va=ϕaiadiadt+ϕaibdibdt+ϕaicdicdt+ϕaθrdθrdt+Rsiavb=ϕbiadiadt+ϕbibdibdt+ϕbicdicdt+ϕbθrdθrdt+Rsibvc=ϕciadiadt+ϕcibdibdt+ϕcicdicdt+ϕcθrdθrdt+Rsic

where

  • va, vb, vc are the voltages applied to the A, B, and C stator windings.

  • ia, ib, ic are the stator currents in each of the three windings.

  • Rs is the resistance of each of the stator windings.

3-D Flux Linkage Data Models

The 3-D flux linkage data options let you work with raw flux linkage data exported from your finite-element (FE) motor design tool. This is in contrast to the 3-D partial derivative data options, for which you need to determine the partial derivatives. You can provide flux linkage data in a variety of formats, to support different FE tool conventions:

  • Tabulate DQ-axes flux linkage data or A-phase flux linkage data — Some tools support working with flux linkage resolved into direct (D) and quadrature (Q) axes. An advantage of this approach is that data for rotor angles in the range 0 to 360/N/3 degrees is required (where N is the number of pole pairs). Other tools work directly with A-, B-, and C-phase flux linkages, and for this you can import just the A-phase flux linkage, for which the rotor angle range must be in the range 0 to 360/N degrees. The implicit assumption of importing just the A-phase data is that the B and C phase data is the same except shifted in phase.

  • Tabulate using cartesian or polar current coordinates — Cartesian tabulation implies the flux linkage is tabulated in terms of D-axis current and Q-axis current (plus rotor angle). Alternatively, polar tabulation involves tabulating flux linkages in terms of current magnitude, current advance angle relative to the Q-axis, and rotor angle. The advantage of polar coordinates is that it more naturally reflects the permitted operating currents, thereby avoiding unused table data points.

These conventions result in four Flux linkage data format parameterization options:

  • D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta)

  • D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta)

  • A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta)

  • A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta)

Besides selecting the flux linkage data format used by your FE tool, you have to select the version of Park transform used by the tool. The four conventions are described below and correspond to the four options for the Park’s convention for tabulated data drop-down menu.

Note

When looking at logged values for D- and Q-axis currents, keep in mind that for each of these options, the format is converted, as needed, so that internally the FEM-Parameterized PMSM block consistently uses Option 1.

Note

To preserve higher-order harmonics due to the permanent magnet back EMF, provide the A-phase flux data rather than the D-axis and Q-axis flux data. Conversely, if you provide D-axis and Q-axis fluxes, the Park's transform removes the higher-order harmonics. Working with D and Q fluxes is sufficient for many applications, particularly if you set the Winding type parameter to Wye-wound and there aren't connections to the neutral port of this block. For this particular case, the constraint that the sum of the currents is zero at the neutral port removes all third-order harmonics.

Option 1. Q leads D, rotor angle measured from A-phase to D-axis

This is the Park’s convention used internally by Simscape Electrical motor and machine blocks. All other options are converted into this format.

  • N: number of pole pairs

  • θr: rotor angle

  • id, iq: D-axis and Q-axis currents

  • ip: Current magnitude = id2+iq2

  • β: Current advance angle = tan1(id/iq)

Corresponding Park transform is

[idiqi0]=23[cos(Nθr)cos(Nθr2π3)cos(Nθr+2π3)sin(Nθr)sin(Nθr2π3)sin(Nθr+2π3)121212][iaibic]

where ia, ib, and ic are the A-phase, B-phase, and C-phase currents, respectively.

Option 2. Q leads D, rotor angle measured from A-phase to Q-axis

  • N: number of pole pairs

  • θr: rotor angle

  • id, iq: D-axis and Q-axis currents

  • ip: Current magnitude = id2+iq2

  • β: Current advance angle = tan1(id/iq)

Corresponding Park transform is

[idiqi0]=23[sin(Nθr)sin(Nθr2π3)sin(Nθr+2π3)cos(Nθr)cos(Nθr2π3)cos(Nθr+2π3)121212][iaibic]

where ia, ib, and ic are the A-phase, B-phase, and C-phase currents, respectively.

Option 3. D leads Q, rotor angle measured from A-phase to D-axis

  • N: number of pole pairs

  • θr: rotor angle

  • id, iq: D-axis and Q-axis currents

  • ip: Current magnitude = id2+iq2

  • β: Current advance angle = tan1(id/iq)

Corresponding Park transform is

[idiqi0]=23[cos(Nθr)cos(Nθr2π3)cos(Nθr+2π3)sin(Nθr)sin(Nθr2π3)sin(Nθr+2π3)121212][iaibic]

where ia, ib, and ic are the A-phase, B-phase, and C-phase currents, respectively.

Option 4. D leads Q, rotor angle measured from A-phase to Q-axis

  • N: number of pole pairs

  • θr: rotor angle

  • id, iq: D-axis and Q-axis currents

  • ip: Current magnitude = id2+iq2

  • β: Current advance angle = tan1(id/iq)

Corresponding Park transform is

[idiqi0]=23[sin(Nθr)sin(Nθr2π3)sin(Nθr+2π3)cos(Nθr)cos(Nθr2π3)cos(Nθr+2π3)121212][iaibic]

where ia, ib, and ic are the A-phase, B-phase, and C-phase currents, respectively.

Calculating Iron Losses

The FEM-Parameterized PMSM block models iron losses according to the parameterization methods you choose for flux and torque.

These iron losses produce heat. The block injects the heat from rotor iron losses into the HR thermal port that represents the rotor thermal mass. The block splits the stator iron losses in three equal parts and injects each part into the stator winding thermal ports, HA, HB, and HC.

Specify open-circuit and short-circuit loss data (permanent magnet motors only)

For the 2-D partial derivative data, 3-D partial derivative data, and 4-D partial derivative data options, with or without thermal ports, the iron loss model is based on the work of Mellor [1]. Iron losses are divided into two terms, one representing the main magnetizing path, and the other representing the cross-tooth tip path that becomes active during field weakened operation.

The term representing the main magnetizing path depends on the induced RMS stator voltage, Vmrms:

POC(Vmrms)=ahkVmrms+ajk2Vmrms2+aexk1.5Vmrms1.5.

This is the dominant term during no-load operation. k is the back emf constant relating RMS volts per Hz. It is defined as k=Vmrms/f, where f is the electrical frequency. The first term on the right-hand side is the magnetic hysteresis loss, the second is the eddy current loss and the third is the excess loss. The three coefficients appearing on the numerators are derived from the values that you provide for the open-circuit hysteresis, eddy, and excess losses.

The term representing the cross-tooth tip path becomes important when a demagnetizing field is set up and can be determined from a finite element analysis short-circuit test. It depends on the RMS emf associated with the cross-tooth tip flux, Vdrms*:

PSC(Vdrms*)=bhkVdrms*+bjk2Vdrms*2+bexk1.5Vdrms*1.5.

The three numerator terms are derived from the values you provide for the short-circuit hysteresis, eddy, and excess losses.

Steinmetz parameterization method

For the 3-D flux linkage data with or without thermal ports, you can also model the iron losses based on the Steinmetz equation. The Steinmetz method scales for different motor speeds or electrical frequencies so that iron loss data is only required as function of motor currents.

If, in the Iron Losses setting, you set the Model parameter to Specify open and short circuit loss data (permanent magnet motors only), the block uses the Steinmetz method, but assumes constant coefficients and no dependency on peak current and current phase advance. Select this option if you have dyno measurements or if you perform an FE analysis to get the iron losses from just open-circuit and short-circuit simulations.

Conversely, if you set the Flux linkage data format parameter to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) , then the block tabulated the coefficients with the Peak current magnitude vector, I and Current advance angle vector, B parameters, so that the iron losses are given by:

Protor(f)=khr(Ip,β)f+kJr(Ip,β)f2+ker(Ip,β)f1.5Pstator(f)=khs(Ip,β)f+kJs(Ip,β)f2+kes(Ip,β)f1.5

where:

  • f is the electrical instantaneous frequency, in Hz, and is equal to the rotor mechanical speed multiplied by the number of pole pairs. This frequency is a variable that changes over time.

  • khr(Ip,β) is the Rotor hysteresis loss coefficient, k_hr(I,B).

  • kJr(Ip,β) is the Rotor eddy current loss coefficient, k_Jr(I,B).

  • ker(Ip,β) is the Rotor excess current loss coefficient, k_er(I,B).

  • khs(Ip,β) is the Stator hysteresis loss coefficient, k_hs(I,B).

  • kJs(Ip,β) is the Stator eddy current loss coefficient, k_Js(I,B).

  • kes(Ip,β) is the Stator excess current loss coefficient, k_es(I,B).

Similarly, if you set the Flux linkage data format parameter to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta), then the iron losses are given by:

Ploss,rotor(f)=khr(id,iq)f+kJr(id,iq)f2+ker(id,iq)f1.5Ploss,stator(f)=khs(id,iq)f+kJs(id,iq)f2+kes(id,iq)f1.5

where:

  • khr(id,iq) is the Rotor hysteresis loss coefficient, k_hr(id,iq).

  • kJr(id,iq) is the Rotor eddy current loss coefficient, k_Jr(id,iq).

  • ker(id,idq) is the Rotor excess current loss coefficient, k_er(id,iq).

  • khs(id,iq) is the Stator hysteresis loss coefficient, k_hs(id,iq).

  • kJs(id,iq) is the Stator eddy current loss coefficient, k_Js(id,iq).

  • kes(id,iq) is the Stator excess current loss coefficient, k_es(id,iq).

Select this option only in conjunction with a motor design tool that can calculate the coefficients. You can export the Steinmetz coefficients lookup tables in Cartesian coordinates (id,iq) or radial coordinates (Ip,β) by using FEM tools such as Motor-CAD or ANSYS® Maxwell®. These coefficients are valid for a range of currents and frequencies. To obtain the right value based on the current state of the machine, this block interpolates the Steinmetz coefficient value at run-time.

For more information about importing Steinmetz coefficients from FEM tools, see the Import IPMSM Flux Linkage Data from Motor-CAD example.

Tabulate with current and speed

For the 3-D flux linkage data with or without thermal ports, you can also model the iron losses by tabulating them independently for rotor and stator.

If you set the Flux linkage data format parameter to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta), the block tabulated the iron losses with the Peak current magnitude vector, I and Current advance angle vector, B parameters, so that the iron losses are given by:

Ploss(Ip,β,w)=tablelookup(Ptable,Ip,β,w)

where w is the Rotor speed vector, w parameter.

Similarly, if you set the Flux linkage data format parameter to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta), then the iron losses are given by:

Ploss(id,iq,w)=tablelookup(Ptable,id,iq,w).

Model Thermal Effects

You can expose thermal ports to model the effects of losses that convert power to heat. To expose the thermal ports, set the Modeling option parameter to either:

  • 2-D partial derivative data | No thermal port — 2-D table lookup parameterization, with options to tabulate in terms of current and rotor angle, but without thermal ports.

  • 2-D partial derivative data | Show thermal port — 2-D table lookup parameterization, with options to tabulate in terms of current and rotor angle, and with thermal ports.

  • 3-D partial derivative data | No thermal port — 3-D table lookup parameterization, based on direct current, quadrature current, and rotor angle, but without thermal ports.

  • 3-D partial derivative data | Show thermal port — 3-D table lookup parameterization, based on direct current, quadrature current, and rotor angle, and with thermal ports.

  • 4-D partial derivative data | No thermal port — 4-D table lookup parameterization, based on the three stator winding currents and the rotor angle, but without thermal ports.

  • 4-D partial derivative data | Show thermal port — 4-D table lookup parameterization, based on the three stator winding currents and the rotor angle, and with thermal ports.

  • 3-D flux linkage data | No thermal port — 3-D table lookup parameterization, based on the flux linkage data without thermal ports.

  • 3-D flux linkage data | Show thermal port — 3-D table lookup parameterization, based on the flux linkage data with thermal ports.

For more information about using thermal ports in actuator blocks, see Simulating Thermal Effects in Rotational and Translational Actuators.

Temperature Dependency for Permanent Magnet Flux

To calculate the temperature dependence of the permanent magnet, the block uses the Permanent magnet flux temperature coefficient parameter, αflux. This parameter determines how much the motor flux decreases for each increase of degree of temperature. The block calculates the flux reduction factor by using this equation:

FluxReductionForTemp=1+αflux(TRTmeas),

where TR is the temperature at the HR port and Tmeas is the value of the Measurement temperature parameter. In this block, the flux decreases linearly with the temperature. This decrease causes the back EMF and torque to also decrease linearly with the temperature by the same amount,

EMF=FluxReductionForTempEMF0τ=FluxReductionForTempτ0

where:

  • τ0 is the torque when the rotor temperature is equal to the value of the Measurement temperature parameter.

  • EMF0 is the EMF when the rotor temperature is equal to the value of the Measurement temperature parameter.

After adjusting the torque based on the temperature, the block further reduces the torque, τ, based on the iron losses.

Temperature Dependency for Stator Resistance

The increase in temperature in the permanent magnet changes the stator resistance. The Resistance temperature coefficient parameter, α, drives this change of the resistance:

Ra=Rs[1+α(TATmeas)]Rb=Rs[1+α(TBTmeas)]Rc=Rs[1+α(TCTmeas)]

where Ra, Rb, and Rc are the temperature-adjusted resistances at each phase and TA, TB, and TC are the temperatures at the HA, HB, and HC ports.

Examples

Assumptions and Limitations

This block has the following limitations:

  • For the 2-D data model, the stator-stator mutual inductance, defined by the Stator mutual inductance, Ms parameter value, is constant during simulation and does not vary with rotor angle. This means that the block is suitable for modeling most PMSM and brushless DC motors, but not switched reluctance motors.

  • The 3-D and 4-D data models assume symmetry, so that the flux linkage dependency on currents and rotor angle for windings B and C can be determined from that for winding A.

  • For the 4-D data model, consider memory requirements when fixing the independent parameter values (three currents and rotor angles). The linear interpolation option uses less memory, but the smooth interpolation option is more accurate for a given independent parameter spacing.

  • The iron losses model assumes sinusoidal currents.

Ports

Conserving

expand all

Electrical conserving port associated with the A-phase connection.

Dependencies

To enable this port, set Winding type to Wye-wound or Delta-wound.

Electrical conserving port associated with the B-phase connection.

Dependencies

To enable this port, set Winding type to Wye-wound or Delta-wound.

Electrical conserving port associated with the C-phase connection.

Dependencies

To enable this port, set Winding type to Wye-wound or Delta-wound.

Since R2024a

Electrical conserving port associated with the a positive-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Since R2024a

Electrical conserving port associated with the b positive-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Since R2024a

Electrical conserving port associated with the c positive-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Since R2024a

Electrical conserving port associated with the a negative-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Since R2024a

Electrical conserving port associated with the b negative-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Since R2024a

Electrical conserving port associated with the c negative-end connection.

Dependencies

To enable this port, set Winding type to Open-end.

Electrical conserving port associated with the neutral phase.

Dependencies

To enable this port, set Modeling option parameter to either

  • 2-D partial derivative data | No thermal port, 2-D partial derivative data | Show thermal port, 3-D partial derivative data | No thermal port, 3-D partial derivative data | Show thermal port, 4-D partial derivative data | No thermal port, or 4-D partial derivative data | Show thermal port and set the Winding type parameter to Wye-wound.

  • 3-D flux linkage data | No thermal port or 3-D flux linkage data | Show thermal port, and set the Winding type parameter to Wye-wound and the Expose neutral port parameter to Yes.

Mechanical rotational conserving port associated with the motor case.

Mechanical rotational conserving port associated with the motor rotor.

Thermal conserving port associated with winding A.

Dependencies

To enable this port, set Modeling option to Show thermal port.

Thermal conserving port associated with winding B.

Dependencies

To enable this port, set Modeling option to Show thermal port.

Thermal conserving port associated with winding C.

Dependencies

To enable this port, set Modeling option to Show thermal port.

Thermal conserving port associated with the rotor.

Dependencies

To enable this port, set Modeling option to Show thermal port.

Parameters

expand all

Parameterization method for the flux and torque. To model the effects of copper resistance and iron losses that convert electrical power to heat, choose the options with thermal ports.

Electrical (2-D Partial Derivative Data Parameterization)

This configuration of the Electrical parameters corresponds to the 2-D Partial Derivative Data block parameterizations, with or without thermal ports. If you are using the 3-D Partial Derivative Data, 4-D Partial Derivative Data, or 3-D Flux Linkage Data parameterization of the block, see Electrical (3-D Partial Derivative Data Parameterization), Electrical (4-D Partial Derivative Data Parameterization), or Electrical (3-D Flux Linkage Data Parameterization) respectively.

Select the parameterization method:

  • Assume constant mutual inductance - tabulate with phase current and rotor angle — This method assumes that the flux linking each winding depends nonlinearly only on the current in that same winding, plus the rotor angle.

  • Assume sinusoidal back emf - tabulate with d- and q-axis currents — This method assumes that the flux linking each winding depends nonlinearly on all stator winding currents. It also assumes that the permanent magnet flux linkage is sinusoidal. This option is usually a good fit for interior magnet PMSMs (or IPMSMs).

Select the configuration for the stator windings:

  • Wye-wound — The stator windings are wye-wound.

  • Delta-wound — The stator windings are delta-wound. The a-phase is connected between ports a and b, the b-phase between ports b and c and the c-phase between ports c and a.

  • Open-end — The windings are in an open-end configuration. The block exposes each end of the windings as electrical connections.

Vector of currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle.

Vector of rotor angles corresponding to the provided flux linkage partial derivatives. The vector must start at zero. This value corresponds to the angle where the A-phase magnetic flux aligns with the rotor permanent magnetic peak flux direction (the direct-axis, or d-axis). The last value, Θmax, must be the rotor angle where the flux linkage pattern peaks again. Therefore, the number of pole pairs is 360/Θmax if Θmax is expressed in degrees. The default value corresponds to a 6 pole-pair motor.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle.

Matrix of the flux linkage partial derivatives with respect to current, defined as a function of current vector and rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns. The default value corresponds to the special case where stator inductance does not depend on stator current or on rotor angle.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle.

Matrix of the flux linkage partial derivatives with respect to rotor angle, defined as a function of current vector and rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns. The default value is [0, -0.16, 0.16, 0; 0, -0.16, 0.16, 0; 0, -0.16, 0.16, 0] Wb/rad, which corresponds to the special case where stator inductance does not depend on stator current.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle.

Vector of d-axis currents corresponding to the provided inductances. The current vector must be two-sided (have positive and negative values).

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Vector of q-axis currents corresponding to the provided inductances. The current vector must be two-sided (have positive and negative values).

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Matrix of the d-axis inductances with respect to current, defined as a function of d-axis and q-axis current vectors.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Matrix of the q-axis inductances with respect to current, defined as a function of d-axis and q-axis current vectors.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Matrix of the permanent magnet flux linkages with respect to current, defined as a function of d-axis and q-axis current vectors. Flux linkage is the flux multiplied by the number of winding turns.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Number of the permanent magnet motor pole pairs.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Specify the way of providing the electromagnetic torque data:

  • Yes — The block calculates the torque from the flux linkage information, as a function of current and rotor angle.

  • No — specify directly — Enter the electromagnetic torque data directly, by using the Torque matrix, T(i,theta) parameter.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle. If you set the Parameterization parameter to Assume sinusoidal back emf - tabulate with d- and q-axis currents, the equation for torque is explicit in terms of the provided matrices.

Specify a matrix of the electromagnetic torque applied to the rotor, as a function of current and rotor angle. This parameter is visible only if Calculate torque matrix? is set to No — specify directly.

Dependencies

This parameter is visible only when you set the Calculate torque matrix? parameter to No — specify directly.

Select one of the following interpolation methods for approximating the output value when the input value is between two consecutive grid points:

  • Linear — Uses an extension of linear algorithm for multidimensional interpolation. Select this option to get the best performance.

  • Smooth — Uses a modified Akima interpolation algorithm. Select this option to produce a continuous surface with continuous first-order derivatives.

For more information on interpolation methods, see the PS Lookup Table (2D) block reference page.

Resistance of each of the stator windings.

Stator-stator mutual inductance, which is assumed to be independent of both current and rotor angle.

Dependencies

This parameter is visible only when you set the Parameterization parameter to Assume constant mutual inductance - tabulate with phase current and rotor angle.

Zero-sequence inductance.

Dependencies

To enable this parameter, set Parameterization to Assume sinusoidal back emf - tabulate with d- and q-axis currents.

Electrical (3-D Partial Derivative Data Parameterization)

This configuration of the Electrical parameters corresponds to the 3-D Partial Derivative Data block variants, with or without thermal ports. If you are using the 2-D Partial Derivative Data, 4-D Partial Derivative Data, or 3-D Flux Linkage Data parameterization of the block, see Electrical (2-D Partial Derivative Data Parameterization), Electrical (4-D Partial Derivative Data Parameterization), or Electrical (3-D Flux Linkage Data Parameterization) respectively.

Select the configuration for the stator windings:

  • Wye-wound — The stator windings are wye-wound.

  • Delta-wound — The stator windings are delta-wound. The a-phase is connected between ports a and b, the b-phase between ports b and c and the c-phase between ports c and a.

  • Open-end — The windings are in an open-end configuration. The block exposes each end of the windings as electrical connections.

Vector of direct-axis currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Vector of quadrature-axis currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Vector of rotor angles corresponding to the provided flux linkage partial derivatives. The vector must start at zero. This value corresponds to the angle where the A-phase magnetic flux aligns with the rotor permanent magnetic peak flux direction (the direct-axis, or d-axis). The last value, Θmax, must be the rotor angle where the flux linkage pattern peaks again. Therefore, the number of pole pairs is 360/Θmax if Θmax is expressed in degrees. The default value corresponds to a 6 pole-pair motor.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding A, defined as a function of the two current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding B, defined as a function of the two current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding C, defined as a function of the two current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to rotor angle, defined as a function of the two current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Specify a matrix of the electromagnetic torque applied to the rotor, as a function of the two currents and the rotor angle.

Select one of the following interpolation methods for approximating the output value when the input value is between two consecutive grid points:

  • Linear — Uses an extension of linear algorithm for multidimensional interpolation. Select this option to get the best performance.

  • Smooth — Uses a modified Akima interpolation algorithm. Select this option to produce a continuous surface with continuous first-order derivatives.

For more information on interpolation methods, see the PS Lookup Table (3D) block reference page.

Resistance of each of the stator windings.

Electrical (4-D Partial Derivative Data Parameterization)

This configuration of the Electrical parameters corresponds to the 4-D Partial Derivative Data block variants, with or without thermal ports. If you are using the 2-D Partial Derivative Data, 3-D Partial Derivative Data, or 3-D Flux Linkage Data parameterization of the block, see Electrical (2-D Partial Derivative Data Parameterization), Electrical (3-D Partial Derivative Data Parameterization), or Electrical (3-D Flux Linkage Data Parameterization) respectively.

Select the configuration for the stator windings:

  • Wye-wound — The stator windings are wye-wound.

  • Delta-wound — The stator windings are delta-wound. The a-phase is connected between ports a and b, the b-phase between ports b and c and the c-phase between ports c and a.

  • Open-end — The windings are in an open-end configuration. The block exposes each end of the windings as electrical connections.

Vector of A-phase currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Vector of B-phase currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Vector of C-phase currents corresponding to the provided flux linkage partial derivatives. The current vector must be two-sided (have positive and negative values).

Vector of rotor angles corresponding to the provided flux linkage partial derivatives. The vector must start at zero. This value corresponds to the angle where the A-phase magnetic flux aligns with the rotor permanent magnetic peak flux direction (the direct-axis, or d-axis). The last value, Θmax, must be the rotor angle where the flux linkage pattern peaks again. Therefore, the number of pole pairs is 360/Θmax if Θmax is expressed in degrees. The default value corresponds to a 6 pole-pair motor.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding A, defined as a function of the three current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding B, defined as a function of the three current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to current in winding C, defined as a function of the three current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Matrix of the A-phase flux linkage partial derivatives with respect to rotor angle, defined as a function of the three current vectors and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

Specify a matrix of the electromagnetic torque applied to the rotor, as a function of the three currents and the rotor angle.

Select one of the following interpolation methods for approximating the output value when the input value is between two consecutive grid points:

  • Linear — Uses an extension of linear algorithm for multidimensional interpolation. Select this option to get the best performance.

  • Smooth — Uses a modified Akima interpolation algorithm. Select this option to produce a continuous surface with continuous first-order derivatives.

For more information on interpolation methods, see the PS Lookup Table (3D) block reference page.

Resistance of each of the stator windings.

Electrical (3-D Flux Linkage Data Parameterization)

This configuration of the Electrical parameters corresponds to the 3-D Flux Linkage Data block variants, with or without thermal ports. If you are using the 2-D Partial Derivative Data, 3-D Partial Derivative Data, or 4-D Partial Derivative Data parameterization of the block, see Electrical (2-D Partial Derivative Data Parameterization), Electrical (3-D Partial Derivative Data Parameterization), or Electrical (4-D Partial Derivative Data Parameterization), respectively.

Select the flux linkage data format used by your FE tool:

  • D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta)

  • D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta)

  • A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta)

  • A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta)

Select the configuration for the stator windings:

  • Wye-wound — The stator windings are wye-wound.

  • Delta-wound — The stator windings are delta-wound. The a-phase is connected between ports a and b, the b-phase between ports b and c and the c-phase between ports c and a.

  • Open-end — The windings are in an open-end configuration. The block exposes each end of the windings as electrical connections.

Whether to expose the neutral port of the block.

If you expose the neutral port, the block also models the zero sequence currents. The zero sequence is parameterized by the Stator zero-sequence inductance, L0 parameter. When you tabulate in terms of iD and iQ, or in terms of current magnitude and phase advance, there is no information about non-linear dependence on the zero-sequence current, and the block introduces a degree of approximation. For more accurate results, particularly for large zero-sequence currents, use the 4-D partial derivative data parameterization option.

Dependencies

To enable this parameter, set Winding type parameter to Wye-wound.

Number of the permanent magnet motor pole pairs. The default value is 4.

Select the order and reference angle for the Park transform mapping the given dq data to the three windings.

  • Q leads D, rotor angle measured from A-phase to D-axis — Quadrature-direct transformation with angle measured with respect to d axis.

  • Q leads D, rotor angle measured from A-phase to Q-axis — Quadrature-direct transformation with angle measured with respect to q axis.

  • D leads Q, rotor angle measured from A-phase to D-axis — Direct-quadrature transformation with angle measured with respect to d axis.

  • D leads Q, rotor angle measured from A-phase to Q-axis — Direct-quadrature transformation with angle measured with respect to q axis.

Vector of direct-axis currents at which the flux linkage is tabulated. The current vector must be two-sided (have positive and negative values).

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Vector of quadrature-axis currents at which the flux linkage is tabulated. The current vector must be two-sided (have positive and negative values).

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Row vector of current magnitudes at which the flux linkage is tabulated. The first element must be zero. The adjacent current value should be small relative to the current values at which magnetic saturation begins to occur. This is because derived flux partial derivatives are ill-defined at zero current, and so are calculated at this first nonzero current instead.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Row vector of current advance angle values at which the flux linkage is tabulated. Current advance angle is defined as the angle by which the current leads the quadrature (Q) axis.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Vector of rotor angles at which the flux linkage is tabulated. The vector must start at zero. The default value corresponds to a 4 pole-pair motor.

If Flux linkage data format is D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) (that is, if you tabulate D and Q flux linkage data), then the rotor angle vector must have four or more points and a range from 0 to 120/N degrees, where N is the number of pole pairs. If Flux linkage data format is A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) (that is, if you tabulate A-phase flux linkage data), then the rotor angle vector must have 3n+1 points, where n>=2, and the range must be from 0 to 360/N degrees.

Matrix of the d-axis flux linkage, defined as a function of the dq currents, and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Matrix of the q-axis flux linkage, defined as a function of the dq currents, and the rotor angle vector. Flux linkage is the flux multiplied by the number of winding turns.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

3-D matrix of d-axis flux linkage values as a function of Peak current magnitude vector, I, Current advance angle, B, and Rotor angle vector, theta.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

3-D matrix of q-axis flux linkage values as a function of Peak current magnitude vector, I, Current advance angle, B, and Rotor angle vector, theta.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

3-D matrix of A-phase flux linkage values, as a function of the dq currents and the rotor angle.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

3-D matrix of A-phase flux linkage values, as a function of Peak current magnitude vector, I, Current advance angle, B, and Rotor angle vector, theta.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

3-D matrix of the electromagnetic torque applied to the rotor, as a function of the dq currents and the rotor angle.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

3-D matrix of the electromagnetic torque applied to the rotor, as a function of Peak current magnitude vector, I, Current advance angle, B, and Rotor angle vector, theta.

If your flux data is given in a different order, you can use the permute function to reorder it. For an example of this reordering, see the associated MATLAB script in Import IPMSM Flux Linkage Data from ANSYS Maxwell.

Dependencies

This parameter is visible only when you set the Flux linkage data format parameter to D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Select one of the following interpolation methods for approximating the output value when the input value is between two consecutive grid points:

  • Linear — Uses an extension of linear algorithm for multidimensional interpolation. Select this option to get the best performance.

  • Smooth — Uses a modified Akima interpolation algorithm. Select this option to produce a continuous surface with continuous first-order derivatives.

For more information on interpolation methods, see the PS Lookup Table (4D) block reference page.

Resistance of each of the stator windings.

Zero-sequence inductance.

Dependencies

To enable this parameter, set Winding type to Delta-Wound or Expose neutral port to Yes.

Iron Losses

For more information on calculating iron losses, see Calculating Iron Losses.

Whether to enable iron losses modeling. The Specify tabulated Steinmetz coefficients and Tabulate with current and speed options are only available if you choose the 3-D flux linkage data | No thermal port or 3-D flux linkage data | Show thermal port variants.

Row vector, of length 3, of the open-circuit iron losses due to hysteresis, Eddy, and excess losses, respectively, at the frequency specified by Electrical frequency at which losses determined.

Dependencies

To enable this parameter, set Model to Specify open and short circuit loss data (permanent magnet motors only)

Row vector, of length 3, of the short-circuit iron losses due to hysteresis, Eddy, and excess losses, respectively, at the frequency specified by Electrical frequency at which losses determined.

Dependencies

To enable this parameter, set Model to Specify open and short circuit loss data (permanent magnet motors only)

Electrical frequency at which the open-circuit and short-circuit iron losses were measured.

Dependencies

To enable this parameter, set Model to Specify open and short circuit loss data (permanent magnet motors only).

The resulting short-circuit RMS phase current when measuring the short-circuit losses.

Dependencies

To enable this parameter, set Model to Specify open and short circuit loss data (permanent magnet motors only)

Hysteresis loss coefficient of the rotor depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Eddy current loss coefficient of the rotor depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Excess current loss coefficient of the rotor depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Hysteresis loss coefficient of the stator depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Eddy current loss coefficient of the stator depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Excess current loss coefficient of the stator depending on the d-axis and q-axis currents. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Hysteresis loss coefficient of the rotor depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Eddy current loss coefficient of the rotor depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Excess current loss coefficient of the rotor depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Hysteresis loss coefficient of the stator depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Eddy current loss coefficient of the stator depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Excess current loss coefficient of the stator depending on the current magnitude and current phase advance. It is used by the Steinmetz equation.

Dependencies

To enable this parameter, set Model to Specify tabulated Steinmetz coefficients and, in the Electrical tab, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Vector of rotor speed at which the iron loss is tabulated.

Dependencies

To enable this parameter, set Model to Tabulate with current and speed and, in the Electrical setting, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Iron losses of the rotor tabulated on the d-axis and q-axis currents, and rotor speed.

Dependencies

To enable this parameter, set Model to Tabulate with current and speed and, in the Electrical setting, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Iron losses of the stator tabulated on the d-axis and q-axis currents, and rotor speed.

Dependencies

To enable this parameter, set Model to Tabulate with current and speed and, in the Electrical setting, set Flux linkage data format to either D and Q axes flux linkages as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta) or A-phase flux linkage as a function of D-axis current (iD), Q-axis current (iQ), and rotor angle (theta).

Iron losses of the rotor tabulated on the current magnitude, current phase advance, and rotor speed.

Dependencies

To enable this parameter, set Model to Tabulate with current and speed and, in the Electrical setting, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Iron losses of the stator tabulated on the current magnitude, current phase advance, and rotor speed.

Dependencies

To enable this parameter, set Model to Tabulate with current and speed and, in the Electrical setting, set Flux linkage data format to either D and Q axes flux linkages as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta) or A-phase flux linkage as a function of peak current magnitude (I), current advance angle (B), and rotor angle (theta).

Mechanical

Inertia of the rotor attached to mechanical translational port R. The value can be zero.

Rotary damping.

Temperature Dependence

To enable these parameters, set Modeling option to Show thermal port.

The temperature for which motor parameters are quoted.

Coefficient α in the equation relating resistance to temperature, as described in Thermal Model for Actuator Blocks. The default value is for copper.

The fractional rate of change of permanent magnet flux density with temperature. It is used to linearly reduce the torque and the induced back EMF as temperature rises.

Thermal Port

To enable these parameters, set Modeling option to Show thermal port.

The thermal mass value for the A, B, and C windings. The thermal mass is the energy required to raise the temperature by one degree.

A 1-by-3 row vector defining the temperature of the A, B, and C thermal ports at the start of simulation.

The thermal mass of the rotor, that is, the energy required to raise the temperature of the rotor by one degree.

The temperature of the rotor at the start of simulation.

The percentage of the main flux path iron losses associated with the magnetic path through the rotor. It determines how much of the iron loss heating is attributed to the rotor thermal port HR, and how much is attributed to the three winding thermal ports HA, HB, and HC.

The percentage of the cross-tooth flux path iron losses associated with the magnetic path through the rotor. It determines how much of the iron loss heating is attributed to the rotor thermal port HR, and how much is attributed to the three winding thermal ports HA, HB, and HC.

References

[1] Mellor, P.H., R. Wrobel, and D. Holliday. “A computationally efficient iron loss model for brushless AC machines that caters for rated flux and field weakened operation.” IEEE Electric Machines and Drives Conference. May 2009.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History

Introduced in R2019b