답변 있음
PV MPPT Tracking Failing PV Array Current or Volatge Goes negative
Hi Ishaan. I found that a perturbation of 1% (Constant2 with value of 1) was too large in the controller. If you reduce the Cons...

5일 전 | 0

답변 있음
Model error in Simulink
It is having problems simulating an ideal op amp with infinite gain. If you intend on configuring the LM386 op amp as an invert...

약 1달 전 | 0

답변 있음
create a variable that changes its value(polynomial equation) for different time periods
Maybe something like this.

약 2달 전 | 1

답변 있음
Adding noise to a PID signal
Hi Nathan, You can use the lsim command to get a general response of your controller. I think you want to see the response when...

약 2달 전 | 0

질문


Why the different response of two Simulink models?
Here is a follow-on question to this original question: How can I remove the few peaks before the overshoot, so I only have the...

3달 전 | 답변 수: 0 | 0

0

답변

답변 있음
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Hi Samuel. I found tuning the derivative to be difficult too. Eventually I settled in on P=3.5, I=850, D=0.01 and N=850. The def...

3달 전 | 0

| 수락됨

답변 있음
Can you let me know how to solve my errors? there are 4 errors in my simulink.
You had two issues. One was the integrators in Current_Controller were implimented using the Memory in the feedback path causing...

4달 전 | 1

| 수락됨

답변 있음
Data type mismatch error in Simulink
I saw a number of other issues in this model. 1) I think the inverter needs a ground reference added on the emitters of the low...

4달 전 | 0

| 수락됨

답변 있음
I need more explanations for the described hydraulic simulation
The pump in this model acts in a fixed displacement mode that produces a given flow rate regardless of its output pressure. When...

5달 전 | 0

답변 있음
Filter background from audio file
Check out this previous answer. A different type of owl, but the same concept. Using Spectrogram to Design a Filter - (mathwork...

5달 전 | 0

답변 있음
Simulation of the step response of a time delay system with a PID controller is contorted.
Those sharp transients in the closed loop response are the echoes of the step input as filtered by the transfer function that ar...

6달 전 | 0

답변 있음
3rd Order ODE on Simulink
I approximated the required doublet input into an update to my comment with a summation of two very short pulse generators.

6달 전 | 0

답변 있음
Why is my step response going down instead of up?
I would focus on your equation for zeta on line 60. It is resulting in a negative value (negative damping=bad!) which gives unst...

6달 전 | 1

| 수락됨

답변 있음
An electric circuit that includes a voltage source E with an internal resistance r, and a load resistance R is shown in the figure.
Probably late for your homework assignment. Can you write the equation for the power dissipated in R leaving R as a variable? Do...

6달 전 | 0

제출됨


Frequency Response Analyzer
Perform frequency analysis of your Simulink model without linearization

6달 전 | 다운로드 수: 58 |

Thumbnail

답변 있음
Unexpected noise in output voltage for buck converter
The Puse Generator has a period of 1/100000 seconds, which is injecting 100 KHz pulses into your system. The ripple is simply th...

11달 전 | 0

답변 있음
Reproduce electric motor maps as images in Matlab Simulink
A similar question was answered suggesting importing the image into Matlab and then using ginput to extract coordinates of the a...

약 1년 전 | 0

답변 있음
Determining time elapsed in between two successive pulses of a signal
I updated your code a bit and fed in an artificial signal. It works but has a slight error due to loop delays running on my comp...

약 1년 전 | 1

| 수락됨

답변 있음
How best to gather signals from all over a SIMULINK model to one subsystem
I moved your root model into a subsystem and used Bus Element Out(s), which was then connected to a new input on "get data" subs...

약 1년 전 | 0

답변 있음
A question about FOC current control for PMSM
The decoupling control is not quite correct for the PMSM motor you are using. You need to insert a multiplier by the number of p...

약 1년 전 | 1

| 수락됨

답변 있음
How to measure the steady state amplitude of a control system output
Try using this app. It injects a sine wave and measures the gain and phase after a number of cycles that you specify. https://w...

약 1년 전 | 0

답변 있음
How to programmatically know if a block is a sink block?
I had to add some complexity to your code to make it work on my sample file. modelfile = 'SinkXY';% Or whatever your model file...

약 1년 전 | 0

답변 있음
Need help with simple Simulink
This seems to do the trick. It produces the following result.

약 1년 전 | 1

| 수락됨

답변 있음
Simulation of a missile valve with Simscape
Hi Tom, A flip-flop will latch the valve shut once the flow reaches the threshold and keep it shut until you manually reset it....

1년 이상 전 | 1

| 수락됨

답변 있음
Coding philosophy : Is using global goto like using a global variable?
The thing about global visibility is that this signal can be accessible anywhere in the entire model, from sub-system to sub-sys...

1년 이상 전 | 1

답변 있음
Calling a function using ode45 in App Designer results in unrecognized function
Note that I had answered my own question.

1년 이상 전 | 0

답변 있음
How make single block diagram with this given parameters?
Hi. If you are using a Transfer Fcn block and have the coefficients defined in your workspace, then enter the equations in the b...

1년 이상 전 | 1

| 수락됨

답변 있음
Frequency domain to Time domain Using IFFT : Symmetric figure problem
Your function produced a vector of complex numbers called "A". The original sequence will be reproduced using ifft(A). But the f...

1년 이상 전 | 0

답변 있음
Substitute s for jw in a transfer function
Matlab uses the reserved constant "i" which is set equal to sqrt(-1). Using your transfer function as defined try the following...