Why are my simulink initial conditions sometimes not met, despite high priority?

조회 수: 3 (최근 30일)
Daniel Trapp
Daniel Trapp 2019년 7월 24일
답변: Martin 2023년 10월 4일
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.tf.PNG
  댓글 수: 1
Hari Krishna Ravuri
Hari Krishna Ravuri 2019년 7월 31일
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.

댓글을 달려면 로그인하십시오.

답변 (1개)

Martin
Martin 2023년 10월 4일
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.