Hi,
Is it possible to configure initial conditions of joint block (e.g. initial position, velocity) as tunable parameters? I'm running the simulink model in Rapid mode. I need to configure the joint initial states as tunable parameters so that I don't have to rebuild the whole model every time I change the initial conditions.
Thanks.
댓글 수: 0
채택된 답변
Lucien Hollins
2020년 11월 17일
Hi,
You will need to make the run-time parameters option visible if you have never used them before. The option to switch individual parameters from compile-time to run-time is colocated with each parameter that is run-time enabled.
Note that run-time parameters are not exactly the same as tunable parameters. Some features may vary slightly from one release to another.
댓글 수: 1
Barnaby Pine
2022년 2월 28일
Thank you!
This answer has really helped me in my endeavours!
Took far too long for me to find this out!
Kind regards,
Barnaby Pine
추가 답변 (1개)
Steve Miller
2019년 4월 2일
Yes, you can. The initial conditions can be configured to be run-time parameters so that you can modify them between simulation runs without compiling.
--Steve