MATLAB Answers

Simulink: To Workspace block, collects only one or two data points (Running in External mode)

조회 수: 19(최근 30일)
Min Seg
Min Seg 29 Nov 2015
I am running a simulink model in external mode, and I get only one data point after the run from "To workspace block". I have tinkered with the settings a lot to get this to work, but I am not able to get more than two data points.
I am using Matlab R2015b, model is running on Arduino Mega 2560. The following are the screenshots of the settings I am using: Model:
To Worksoace block setting:
Solver settings:
Data Import/Export:

  댓글 수: 0

로그인 to comment.

채택된 답변

Boris
Boris 12 Dec 2015
Unfortunately I have the same problem. It worked fine with R2014b and doesn't work with R2015a and R2015b.
If you (or someone else) finds a solution, I'm very interested.

  댓글 수: 1

Boris
Boris 9 Mar 2016
How can my answer be the accepted one? I just said I have the same problem and still have the problem.

로그인 to comment.

More Answers (4)

Min Seg
Min Seg 1 Mar 2016
I have tried 2014b and that seems to work fine.

  댓글 수: 1

로그인 to comment.


Vidya Viswanathan
Vidya Viswanathan 1 Apr 2016
Hi,
I notice that in your model, the sample rate used is 6ms. Typically, the gap in output data is observed when the sample rate is less than 10ms because the target tries to upload the data to the host every few seconds.
To resolve the issue,
1) Please increase the duration further in your model and see if it satisfies your requirements. Ideally, it is not recommended to run external mode on Arduino targets at very high rates (such as 1 ms).
2) If your requirement is to have data archiving at very high speeds, it is recommended to use a serial block for data upload. You would then use an ICT receive block on the Host to log data into MATLAB.
I hope this addresses your query.
Regards,
Vidya Viswanathan

  댓글 수: 1

N Kando
N Kando 26 Jan 2017
I am encountering the same issues with the MinSeg.
The dynamic data goes to scope without issue, but only the final value goes to the workspace.
I have tried an (inherited) simulation step of 0.1 [s], and also set the decimation to 10. This did not have any effect; only the final value appears.
[r2015b]

로그인 to comment.


Auralius Manurung
Auralius Manurung 26 Feb 2016
I am having the same problem in R2015b. Any update on this issue will be very much appreciated.

  댓글 수: 0

로그인 to comment.


Giorgio Concu
Giorgio Concu 6 Dec 2017
I had the same problem and I fix it just upgrading to R2016b.

  댓글 수: 0

로그인 to comment.