Simulink: To Workspace block, collects only one or two data points (Running in External mode)

조회 수: 40 (최근 30일)
I am running a simulink model in external mode, and I get only one data point after the run from "To workspace block". I have tinkered with the settings a lot to get this to work, but I am not able to get more than two data points.
I am using Matlab R2015b, model is running on Arduino Mega 2560. The following are the screenshots of the settings I am using: Model:
To Worksoace block setting:
Solver settings:
Data Import/Export:

채택된 답변

Boris
Boris 2015년 12월 12일
Unfortunately I have the same problem. It worked fine with R2014b and doesn't work with R2015a and R2015b.
If you (or someone else) finds a solution, I'm very interested.
  댓글 수: 2
Boris
Boris 2016년 3월 9일
How can my answer be the accepted one? I just said I have the same problem and still have the problem.

댓글을 달려면 로그인하십시오.

추가 답변 (5개)

Min Seg
Min Seg 2016년 3월 1일
I have tried 2014b and that seems to work fine.

Vidya Viswanathan
Vidya Viswanathan 2016년 4월 1일
Hi,
I notice that in your model, the sample rate used is 6ms. Typically, the gap in output data is observed when the sample rate is less than 10ms because the target tries to upload the data to the host every few seconds.
To resolve the issue,
1) Please increase the duration further in your model and see if it satisfies your requirements. Ideally, it is not recommended to run external mode on Arduino targets at very high rates (such as 1 ms).
2) If your requirement is to have data archiving at very high speeds, it is recommended to use a serial block for data upload. You would then use an ICT receive block on the Host to log data into MATLAB.
I hope this addresses your query.
Regards,
Vidya Viswanathan
  댓글 수: 1
N Kando
N Kando 2017년 1월 26일
편집: N Kando 2017년 1월 26일
I am encountering the same issues with the MinSeg.
The dynamic data goes to scope without issue, but only the final value goes to the workspace.
I have tried an (inherited) simulation step of 0.1 [s], and also set the decimation to 10. This did not have any effect; only the final value appears.
[r2015b]

댓글을 달려면 로그인하십시오.


Auralius Manurung
Auralius Manurung 2016년 2월 26일
I am having the same problem in R2015b. Any update on this issue will be very much appreciated.

Giorgio Concu
Giorgio Concu 2017년 12월 6일
I had the same problem and I fix it just upgrading to R2016b.

Number seven
Number seven 2022년 3월 10일
I was having a similar issue where no data was being output to the workspace. I fixed it by going to tab Code > External mode control panel > Data Archiving. Then here I enabled Data Archiving, selected a directory and typed my desired file name. Now I have my variable in the To Workspace block being written to workspace, although I also get a file in the same directory with the name I set in Data Archiving.