errors when generating certain motions of Revolute Joint in simMechanics

조회 수: 24 (최근 30일)
QiQin Zhan
QiQin Zhan 2015년 3월 18일
댓글: Mohammad 2025년 5월 29일
The model:
The simMechanics system is as follow:
simin is input from workspace and is the motion of Revolute Joint as the time goes on.
But it shows some kind of error: In the dynamically coupled component containing Revolute Joint Revolute_Joint, there are fewer joint primitive degrees of freedom with automatically computed force or torque (0) than with motion from inputs (1). The prescribed motion trajectories in this component may not be achievable. Solve this problem by reducing the number of joint primitives with motion from inputs or increasing the number of joint primitives with automatically computed force or torque. Resolve this issue in order to simulate the model.
Does anybody knows what's wrong and what should I do to solve the problem.
  댓글 수: 3
Naseeb Gill
Naseeb Gill 2017년 3월 2일
Hello @Shuangjun, I am also facing same problem and I changed actuation force to automated computed but the problem is same. Image showing error attached. Can you please help me to resolve this.
Mohammad
Mohammad 2025년 5월 29일
I believe another reason for your error is that you need to go to (Simulink PS-Converter) and turn the second order differentiation. First test your simulink by giving a sin input, then try to import your variables

댓글을 달려면 로그인하십시오.

답변 (1개)

Steve Miller
Steve Miller 2017년 8월 5일
편집: Steve Miller 2017년 8월 5일
I suspect all you need to do in the model pictured above is set the Torque setting to "Automatically Computed" in your Revolute joint.
To configure motion actuation at a Revolute Joint, you make two changes as shown in the image below. This lets you perform inverse dynamics simulation with Simscape Multibody, where the simulation tells you the forces and torques required to achieve a desired motion trajectory.
You can solve very challenging inverse dynamics problems with Simscape Multibody, including prescribing the motion along one degree of freedom and determining the required force/torque at other degrees of freedom. For more details, see the documentation page Specifying Joint Actuation Inputs.
Attached to this answer is a modified version of shipping example sm_four_bar where one input is driven with motion actuation. Please note the settings within the Simulink-PS block, including units and input filtering. When possible, let Simscape calculate a consistent set of derivatives for you (see documentation page Specifying Motion Input Derivatives).
Thanks,
--Steve
  댓글 수: 4
Victor Gheorghiu
Victor Gheorghiu 2025년 4월 8일
The illustration above must be included in the help as a note in such cases!
It is much more impressive than the simscape error message.
This error message is so poor in information that you can't do anything with it!
Mohammad
Mohammad 2025년 5월 29일
@Joben Kennard Arroyo when you controlling the position only, if your signal is coming from a continous source or workspace, perhaps you need to go to Simulink Ps-Converter block, turn on the filtering and decond second order. This way it will calculate the speed and acceleration as well

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Assembly에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by