photo

Kevin Chien

MathWorks

Last seen: 3일 전 2017년부터 활동

Followers: 0   Following: 0

메시지

통계학

  • Revival Level 1
  • Knowledgeable Level 1
  • First Answer

배지 보기

Feeds

보기 기준

답변 있음
How to disable livelock prevention on SimEvents?
There are some workarounds: (1) registering events on one block(say, Entity Generator) with time offsets: for example, event ...

거의 7년 전 | 0

답변 있음
Simevents export entity attributes to workspace at Terminator
You can output statistics of Entity Terminator block by enabling the checkbox inside Statistics panel. Please see the attached p...

대략 7년 전 | 0

답변 있음
Strange behavior gate by adding a queue
I downloaded the model and ran the simulation - both production lines returned the same results. Sometime scopes present values ...

대략 7년 전 | 0

답변 있음
Simulink Simevents output current state of an entity server
If you double-click on Entity Server to open the property panel, you will see the 4th tab, "Statistics". After selecting the sta...

대략 7년 전 | 0

답변 있음
Which data type should I introduce via control port in entity output switch?
You need to use [Message Send] block to convert any signal to message, and connect to the control port of [Output switch]. P...

대략 7년 전 | 2

| 수락됨

답변 있음
Simlink Simevents store event time in entity attribute
There is a simple example in SimEvents design patterns. Open SimEvents library, click on [Design Patterns] block (which locat...

대략 7년 전 | 1

| 수락됨

답변 있음
queue initial condition, store entities in queue at start up
Please refer to the answer here: <https://www.mathworks.com/matlabcentral/answers/343475-simulink-simevents-save-and-reload-curr...

대략 7년 전 | 0

답변 있음
Simulink Simevents save and reload current state/status
If you are using 2016a or later versions of SimEvents, it shall support SimState feature. I just give it a shot in SimEvents and...

대략 7년 전 | 0