photo

Sumukh


2024년부터 활동

Followers: 0   Following: 1

Pronouns:
He/him

통계학

  • Knowledgeable Level 2
  • First Answer

배지 보기

Feeds

보기 기준

답변 있음
Tuning of box jenkins model parameters to improve accuracy
Hi John, The model obtained from “bj” function can be tuned in the same way as the models obtained from “oe” and “arx” function...

2일 전 | 0

답변 있음
How can I increase the speed of scheme simulation?
Hi stepa, The provided model is stiff and has both fast and slow-changing components. The “Solver” used in the “Configuration P...

2일 전 | 0

답변 있음
Unable to start MATLAB. Error 6100.
Hi Joshua. I had faced the same issue earlier. “Error 6100” would appear sporadically when I used MATLAB Docker image. However,...

3일 전 | 0

답변 있음
Create single custom simscape component which contains multiple subsystems?
Hi Daniel. There are two possible ways to create a single protected component for Simscape subsystem with nested subsystems: A...

4일 전 | 0

답변 있음
Three-Phase V-I Measurement with 4 wires
Hi M., The “Three-Phase VI Measurement” block available in Simscape Specialized Power System (SPS) library, is for measurement ...

5일 전 | 0

답변 있음
Missing a continuous variable resistor for Specialized Power Systems
Hi Thomas. There is no “Continuous” simulation-type “Variable Resistor” block available in Simscape Specialized Power Systems (...

5일 전 | 0

답변 있음
Issue with Increasing Time Step in "Two-Zone MVDC Electric Ship" Model
Hi Ali. The MVDC model has a default time step of 25e-6 and runs for 30 sec. So, increasing the time-step to 1e-4 throws an err...

6일 전 | 0

답변 있음
Two different models for the stepper motor in Simscape stepper motor blocks
Hi Ayham. The stepper motor blocks available in Simscape Electrical and Simscape Specialized Power Systems (SPS) libraries use ...

6일 전 | 0

답변 있음
How is the Simulink total block I/O size calculated exactly? It would help me prevent the I/O buffer size error
Hi v k. MATLAB documentation does not provide details regarding how exactly the total block I/O size in Simulink is calculated...

20일 전 | 1

| 수락됨

답변 있음
How to configure HRPWM module on the F28379D TI LaunchPad
Hi Jeffrey. Based on the description you have provided, I get the understanding that you want to use the PWM/DAC functionality ...

25일 전 | 0

답변 있음
How to extract state values of function slewrate() / Get Upper state values bimodal waveform
Hi Jemp. The “slewrate” function has few name-value pair arguments that can be passed into it, as per the following documenta...

26일 전 | 0

답변 있음
Divide Matrix into smaller matrices
Hi Max. To divide the matrix into multiple matrices, please check out the following code: arr_temp=1:2000; % To store the 2000...

26일 전 | 0

답변 있음
I want to change the parameters of the Synchronous Machine Model 1.0 according to the rpm.
Hi Dongwon. You want to change the synchronous machine parameters based on certain pre-defined relationship between rpm and ma...

27일 전 | 0

| 수락됨

답변 있음
How do I connect PS Variable Delay Block to a Constant Current Load block
Hi David. I understand that you are trying to introduce a delay of 120 degrees to the current through the load. However, the c...

대략 1개월 전 | 0

| 수락됨

답변 있음
How to access a Fixed Point convert Look up table
Hi Minas. I understand that you are trying to access the lookup table generated from HDL coder for the “hankel” function. A...

대략 1개월 전 | 1