Qing Liu
Followers: 0 Following: 0
Feeds
답변 있음
This model is configured for concurrent execution and has modeling constraints. Input port 1 of xx block must be contiguous. what's that mean?
Hi, Xu Liu, When I mux signals in a subsystem, and demux them in another concurrent subsystem, I get the this error. But I ...
This model is configured for concurrent execution and has modeling constraints. Input port 1 of xx block must be contiguous. what's that mean?
Hi, Xu Liu, When I mux signals in a subsystem, and demux them in another concurrent subsystem, I get the this error. But I ...
거의 2년 전 | 0
질문
The propose of 2 uploadInfos in external mode?
In external mode, BdUploadInfo data structure describes the data that need to be upload to the host(Simulink). /* * The BdUplo...
2년 초과 전 | 답변 수: 0 | 0
0
답변답변 있음
How can you generate a C code with embedded coder from a simulink model with a cycle time/period (sample time) shorter than 1 ms?
A tricky method : manually modify the tlc file( <MATLAB_ROOT>/rtw/c/tlc/mw/ertwinthread.tlc ) comment out lines 773-780 (as fol...
How can you generate a C code with embedded coder from a simulink model with a cycle time/period (sample time) shorter than 1 ms?
A tricky method : manually modify the tlc file( <MATLAB_ROOT>/rtw/c/tlc/mw/ertwinthread.tlc ) comment out lines 773-780 (as fol...
4년 초과 전 | 0
| 수락됨
답변 있음
Is concurrent execution not possible for a Simulink model with sample time less than 1ms ?
I answered the same question here: https://www.mathworks.com/matlabcentral/answers/446466-how-can-you-generate-a-c-code-with-e...
Is concurrent execution not possible for a Simulink model with sample time less than 1ms ?
I answered the same question here: https://www.mathworks.com/matlabcentral/answers/446466-how-can-you-generate-a-c-code-with-e...
4년 초과 전 | 0