why doesn't my hard stop in Double-Acting Actuator (IL-G) work?
The answer is the stiffness of the stop was too small. The default value of stiffness 1e6 was allowing the piston to keep movin...
why doesn't my hard stop in Double-Acting Actuator (IL-G) work?
The answer is the stiffness of the stop was too small. The default value of stiffness 1e6 was allowing the piston to keep movin...
거의 5년 전 | 0
| 수락됨
질문
why doesn't my hard stop in Double-Acting Actuator (IL-G) work?
I am using a Linear actuator with piston motion controlled by opposing hydraulic and gas chamber, which allows the setting of t...