How does using multiple SimPowerSystems Ideal Switch blocks in series with snubber impedances compare with reality in my power network in SimPowerSystems 4.3 (R2006b)?
조회 수: 3 (최근 30일)
이전 댓글 표시
When using multiple ideal switches in series, the snubber circuit must be used. A high value resistance value is then added to allow simulation to work. I am presently building power distribution networks using the Ideal Switch block as the main building block to create virtual power contactors which are then assembled together to create large network of power contactors. I must use the snubber in order to allow this environment to simulate. I would like to know how does using Ideal Switch blocks in series in such a manner compares with reality. My example model is attached as "Basic_network_topology.mdl".
채택된 답변
MathWorks Support Team
2009년 6월 27일
If you build a real circuit with two switches connected in series as in your example "Basic_network_topology.mdl", the voltage appearing across switches when both switches are opened will be dictated by the stray capacitance of each individual switch and by their capacitances to ground. We can assume that the resistive leakage current is negligible.
For a mechanical switch this stray capacitance can be evaluated based on the
switch geometry or it can be measured.
In your example, if you replace the resistive snubber by capacitive snubbers
by setting
Rs=0 and Cs=10e-12
(assuming 10 pF stray capacitances), you will still obtain 50 V across each switch. See example model "Basic_network_topologyGS.mdl".
Now, if the capacitances are
Cs1= 10 pF and Cs2=30 pF
you get
Vsw1= 75 V and Vsw2 = 25 V.
Naturally, if you use a Voltage sensor with given input impedance, the voltage sharing will be affected. For example, using a voltage sensor with 10-Megohm resistive input impedance to measure Vsw1 and Cs1=Cs2= 10 pF will give
Vsw1| ~0 V Vsw2=100 V
If the voltage source is an AC source of 60 Hz and 100V peak voltage, you would get Vsw1 = 3.8 V peak and Vsw2 = 99.8 V .
In other words, the voltage sharing is highly dependant on the stray capacitances and voltage sensors input impedances as it would be in the real life.
댓글 수: 0
추가 답변 (0개)
참고 항목
카테고리
Help Center 및 File Exchange에서 Electrical Block Libraries에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!