Rte Explicit Read inside if condition

조회 수: 5 (최근 30일)
gianluca cenerelli
gianluca cenerelli 2021년 5월 14일
이동: Walter Roberson 2024년 8월 18일
Dear all
could you please help me with the following problem?
I have to to an Rte Explicit read (AUTOSAR) port inside an if block. I've tried several solutions (enabled sub-systems, if action, function call) but it generates the code with the Rte read in the if condition, but it adds another variable that I don't want in the final code.
Then at the end I need a code like this:
if (condition){
Rte_Read_XXX(&tmp);
}
But what I tried generates the following code:
if (condition){
Rte_Read_XXX(&tmp);
Var = tmp;
}
and then uses Var. I don't want it to create this additional variable.
NOTE: I'm using MATLAB 2016B and Embedded Coder.

답변 (1개)

Anurag Ojha
Anurag Ojha 2024년 8월 18일
이동: Walter Roberson 2024년 8월 18일
Hey
The issue arises because when using 'ExplicitReceive' mode, Simulink automatically buffers the data to ensure simulation and code behavior match. This often results in an additional variable in the generated code.
You can refer to following links for more infromation:

카테고리

Help CenterFile Exchange에서 AUTOSAR Blockset에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by