필터 지우기
필터 지우기

Simscape Error ; The following Inductors are connected together

조회 수: 28 (최근 30일)
Sreeraj A
Sreeraj A 2021년 3월 24일
댓글: Sreeraj A 2021년 3월 26일
Hello,
I have a Boost PFC which I am trying to convert to interleaved architecture when tried running the simulation getting the error
Thanks in Advance.
  댓글 수: 1
hamza hamid
hamza hamid 2021년 3월 24일
Please me your Simulation model I will check the problem. This my email:hamidamza@yahoo.fr I have Matlab 2016b

댓글을 달려면 로그인하십시오.

채택된 답변

Joel Van Sickel
Joel Van Sickel 2021년 3월 24일
You can place a large resistor between the two inductors and connect it to ground. Start with 1e6 ohms.
Regards,
Joel
  댓글 수: 3
Joel Van Sickel
Joel Van Sickel 2021년 3월 25일
yes, that should be fine, but to see how much it is affecting your simulation, you can measure the current going through the resistor. If it is above 1-2% of your system current, you may want to make it larger. (the smaller the resistor, the more innacurate your model will be, but the faster it can simulate. The larger the resistor, the more accurate, but the slower the model might run).
Sreeraj A
Sreeraj A 2021년 3월 26일
Hello Joel,
Thank you very much for the information and support. Much appreciated.
Regards.

댓글을 달려면 로그인하십시오.

추가 답변 (0개)

커뮤니티

더 많은 답변 보기:  Power Electronics Community

카테고리

Help CenterFile Exchange에서 Simscape Electrical에 대해 자세히 알아보기

제품


릴리스

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by