Hi, I made level 2 s-function in C language, which sends some data via serial port. I compiled it with Microsoft Visual C++ 2008 SP1 compiler. When I add this s-function to simulink model and start the simulation in normal mode, everything is ok, but, when I want to connect with realtime target (after building with rtwin.tlc), I get this error message:
Error occurred while executing External Mode MEX-file 'rtwinext': Error loading real-time executable: undefined symbol "_InterlockedExchangeAdd"
I have not any idea, what this error means. Could anybody help me? Thanks.
댓글 수: 2
Kaustubha Govind
2013년 6월 4일
Do you think the failure is specific to your S-function, or do you see it even without your S-function. For example, you could try the example model 'rtvdp' and see if you can execute that in external mode successfully.
채택된 답변
Jan Houska
2013년 6월 5일
For serial port communication, please use Packet Output or Stream Output blocks, depending on your data format. You are correct that you cannot use Windows API in real-time code.
추가 답변 (1개)
Jan Houska
2013년 6월 6일
If you want to react to individual received bytes, it is probably best to sample (poll) the input fast enough. I'd recommend the Packet Input block with a sample rate of, say, 0.5ms, and using its Data Ready output to trigger any necessary action.