필터 지우기
필터 지우기

How to apply a appropriate sampleing frequency and cut off frquency for a low pass filter

조회 수: 3 (최근 30일)
hello, if you have a set of raw data like this how can you set a appropriate sampling frequency and cut off frequency?
Because I know that the table above provided a sampling frequency of Fs = 0.01 so I'm wondering if you change the value of Fs in the code, will it affect the filtered plot?
Thank you

채택된 답변

Star Strider
Star Strider 2021년 2월 12일
Because I know that the table above provided a sampling frequency of Fs = 0.01 ...
That is not the sampling frequency. It is the sampling interval, and should actually be:
Ts = 0.01; % Sampling Interval
Fs = 1/Ts; % Sampling Frequency
Fn = Fs/2; % Nyquist Frequency
The sampling interval and sampling frequency cannot be changed, and produce meaningful output. The filter must use the information provided in the signal.
The cutoff (passband) frequency must be greater than 0 and less than the Nyquist frequency. What it is depends on what you want the filter to do.
  댓글 수: 4
Star Strider
Star Strider 2021년 2월 12일
As always, my pleasure!
Of course, they do not change. Only the filter characteristics change, depending on what you want the filter to do.