Simscape Electrical conversion to Simulink and back

조회 수: 13 (최근 30일)
Anish Joshi
Anish Joshi 2020년 12월 29일
답변: David John 2021년 12월 6일
Hello,
I have used Simulink for a long time but I am new to Simscape. I am trying to build a model of a DC motor controlled using a H Bridge. Just to try something out, I want to connect the BRK port of the H Bridge to a signal coming from Simulink, using the Simulink-PS convertor block. But I am unable to do so as you can see in the attached picture.
Is this not the right way to connect Simulink to PS?
Thanks,
Anish

채택된 답변

David John
David John 2021년 12월 6일
BRK is an electrical signal, so it needs to come out of a voltage source instead of directly from a Simulink-PS Converter.
Try adding a Controlled Voltage Source between REF and BRK, and connect your Physical Signal to the control node.

추가 답변 (0개)