GigE Camera Error: Unable to set PacketSize
조회 수: 14 (최근 30일)
이전 댓글 표시
I'm trying to connect a GigE camera through a pleora PT1000 IP engine. I'm using Matlab 2012a. I'm getting an error of "gige: Unable to set PacketSize" when trying to preview or use getsnapshot. I've seen on a previous thread the same problem using 2010. The help there has not solved my problem. Any help would be greatly appreciated.
댓글 수: 1
jonathan
2013년 7월 25일
I'm getting this same exact issue with the same pleora device. Have you found a solution to this yet?
답변 (1개)
Evan
2013년 7월 25일
편집: Evan
2013년 7월 25일
Have you tried setting the Packet Size property for your camera? Outside of matlab, you should make sure Jumbo Frames are enabled and set the value to the maximum allowed by your network card by going to:
Control Panel > Device Manager > Network Adaptors > Network Card Name > Advanced > Jumbo Frames
Then, in matlab, set 'PacketSize' to that value:
src.PacketDelay = value;
댓글 수: 2
jonathan
2013년 7월 26일
I did this, but forgot to set PacketSize in matlab as well. After imaqreset, it worked like a charm.
참고 항목
카테고리
Help Center 및 File Exchange에서 GigE Vision Hardware에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!