GigE Camera Error: Unable to set PacketSize

조회 수: 14 (최근 30일)
John
John 2013년 3월 28일
I'm trying to connect a GigE camera through a pleora PT1000 IP engine. I'm using Matlab 2012a. I'm getting an error of "gige: Unable to set PacketSize" when trying to preview or use getsnapshot. I've seen on a previous thread the same problem using 2010. The help there has not solved my problem. Any help would be greatly appreciated.
  댓글 수: 1
jonathan
jonathan 2013년 7월 25일
I'm getting this same exact issue with the same pleora device. Have you found a solution to this yet?

댓글을 달려면 로그인하십시오.

답변 (1개)

Evan
Evan 2013년 7월 25일
편집: Evan 2013년 7월 25일
Have you tried setting the Packet Size property for your camera? Outside of matlab, you should make sure Jumbo Frames are enabled and set the value to the maximum allowed by your network card by going to:
Control Panel > Device Manager > Network Adaptors > Network Card Name > Advanced > Jumbo Frames
Then, in matlab, set 'PacketSize' to that value:
src.PacketDelay = value;
  댓글 수: 2
jonathan
jonathan 2013년 7월 26일
I did this, but forgot to set PacketSize in matlab as well. After imaqreset, it worked like a charm.
Evan
Evan 2013년 7월 26일
Great!