필터 지우기
필터 지우기

Can somebody run this code for me, It's taking too much time for me

조회 수: 2 (최근 30일)
Ajmal R S
Ajmal R S 2020년 10월 7일
댓글: Stephen23 2020년 10월 9일
clc;
clear all;
T2_0 = 320.1;
tspan = [0 50];
[t2sol,T2sol] = ode45(@(t,T2) heat2(t,T2), tspan, T2_0);
plot(t2sol,T2sol)
grid on
xlabel('t')
ylabel('T2')
title('Solutions of Heat Balance on Tank-2')
This is a code that I modelled to study about Stirred Tank Heater Performance
function dT2 = heat2(t,T2)
% Inputs
A2 = 7.854e-05; %Cross-Sectional Area Tank 2
Tc = 303; %Cooling Water Temp
T1 = 325.4; %Tank 1 Temp
Ta = 298; %Atmospheric Temp
h2 = 0.41; %Level h2
R2 = 0.05; %Radius Tank 2
rho_w = 1000; %Density in kg/m3
Cp = 4182; %Cp value in J/KgK
U = 235.1043; %Heat Transfer Coeff
u1 = 0.45; %Flow F1
F1_A = 8.0368e-11;
F1_B = 456.85e-11;
F1_C = 42379e-11;
F1 = F1_A*(u1^3)-F1_B*(u1^2)+F1_C*(u1);
u2 = 0.45; %Flow F2
F2_A = 1.2943e-11;
F2_B = 190.64e-11;
F2_C = 8796.8e-11;
F2_D = 196620e-11;
F2 = -F2_A*(u2^4)+F2_B*(u2^3)-F2_C*(u2^2)+F2_D*(u2);
u3 = 0.45; %Flow F3
Fr_A = (1/1800)*1e-03;
Fr = Fr_A*u3;
u5 = 0.45; %Heat Input Q2
Q2_A = 14.4;
Q2_B = 0.96;
Q2_C = 0.008;
Q2 = Q2_A*(u5)-Q2_B*(u5^2)-Q2_C*(u5^3);
dT2 = (F1*(T1-T2)+F2*(Tc-T2)-Fr*(T2-T1)+(Q2-(2*pi*R2*h2*U*(T2-Ta)))/rho_w*Cp)/(A2*h2);
end
And this is the function "heat2" shown in code. Can Anybdody what output this shows. Since it's taking a really long time for and my laptop is heating up and switching off before it completes
Thank you

채택된 답변

Ameer Hamza
Ameer Hamza 2020년 10월 7일
Use a stiff solve, ode15s()
[t2sol,T2sol] = ode15s(@(t,T2) heat2(t,T2), tspan, T2_0);

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Ordinary Differential Equations에 대해 자세히 알아보기

태그

제품


릴리스

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by