Matlab 2019b don't recognise "Data Acquisition Commands"
조회 수: 11 (최근 30일)
이전 댓글 표시
I have been trying to connect NI USB 6009 to Matlab 2019b
Session base commands are recognised
I want to send Digital OUT signal ,but the "Session Commands" to ON or OFF Digital Output i cannot figure out
When i use these commands ,its working
d = daq.getDevices;
s = daq.createSession('ni');
sig = addDigitalChannel(s,'Dev1','port0/line0','OutputOnly');
signalData = sin(pi/2);
startBackground(s);
Following Messages i have
I want to use Data Acquisition Following are the commands i want to use , but the Matlab dont recognise them;
>> d = daqlist("ni")
Unrecognized function or variable 'daqlist'.
>> d = daqlist("ni")
Unrecognized function or variable 'daqlist'.
>> daq("ni")
Unrecognized function or variable 'daq'.
I have already checked the Data Acqusition Toolbox is installed. but Data Acqusition Commands are not recognisable.
댓글 수: 0
답변 (1개)
Walter Roberson
2020년 7월 29일
편집: Walter Roberson
2020년 7월 29일
daqlist is new in R2020a
댓글 수: 2
Walter Roberson
2020년 7월 29일
The article says clearly that you cannot use startForeground or startBackground with digital pins for a fair number of National Instrument DAQs, and that even for the ones that permit using those calls, that it is often restricted as to which pins can be used.
The NI USB 6009 is a fairly low-end model. You probably cannot use the calls with any of the digital pins for the USB6009.
Using outputSingleScan is the way to proceed for the digital pins.
참고 항목
카테고리
Help Center 및 File Exchange에서 Data Acquisition Toolbox에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!