hi
i build the mathematical model for the induction motor using ABC to DQ equation
now I have difficulty to simulate faults like broken bar or short circuit fault in stator winding..
how i can do it in simulink ?
I would be grateful for your help
thanks.
  댓글 수: 2
shubhranshu sharma
shubhranshu sharma 2021년 9월 28일
if any one did stator fault of IM in simulink please send.i will be very gratefull to you.thanks
i am also trying but facing difficulty. please send to- shubhranshusharma23@gmail.com
BIPIN BIPIN
BIPIN BIPIN 2022년 11월 17일
Please send me also. I am also facing difficulty. bky4496@gmail.com

댓글을 달려면 로그인하십시오.

답변 (1개)

Joel Van Sickel
Joel Van Sickel 2022년 11월 21일
You should use simscape models instead of simulink models, or you should derive a simulink model that is specifically designed the type of faults you want to inject. d/q transformations limit the types of faults that you can model, and equations typically change once a fault is injected so you will often need multiple sets of equations. Simscape models will support a set of predefined faults so that you are less likely to need a custom model, but not all possible faults can be included, so you have to read the documentaiton for the specific component that you are interested in.