Hii....I came across this error while making a model..
Simulink cannot solve the algebraic loop containing 'trial_3/PV panel/PV module' at time 0.0 using the TrustRegion-based algorithm due to one of the following reasons: the model is ill-defined i.e., the system equations do not have a solution; or the nonlinear equation solver failed to converge due to numerical issues. To rule out solver convergence as the cause of this error, either a) switch to LineSearch-based algorithm using set_param('trial_3','AlgebraicLoopSolver','LineSearch') b) reducing the VariableStepDiscrete solver RelTol parameter so that the solver takes smaller time steps. If the error persists in spite of the above changes, then the model is likely ill-defined and requires modification.
I am using coding to make photovoltaic panel and MPPT P&O algorithm.
Please help me to solve this error.

댓글 수: 4

ahmed altaee
ahmed altaee 2017년 1월 27일
i have the same problem!! :(
Rajesh Laguri
Rajesh Laguri 2018년 4월 2일
Have you done this, can you please suggest how you solved this issue.I am also coding for same.
Jim Riggs
Jim Riggs 2019년 12월 2일
It's true that you can break algebraic loops using a unit delay as Azzi Abdelmalek says, but judging by the comments, people are not reviewing the link provided by Walter Roberson, below. This article contains some important information and considerations on the effect of using a unit delay and provides an alternative solution.
Malaiyappan M
Malaiyappan M 2020년 8월 17일
in MPPT Buck/Boost Converer try adjust the Inductor Value to resolve this error

댓글을 달려면 로그인하십시오.

 채택된 답변

Azzi Abdelmalek
Azzi Abdelmalek 2012년 11월 23일
편집: Azzi Abdelmalek 2012년 11월 23일

19 개 추천

Algebraic loop occurs often, when you have a feedback through a constant block or equivalent, which means your signal y(t0)=constant * y(t0) , you should have y(t0+1)=constant*y(t0) which you can get with a unit delay block

댓글 수: 15

billel madridi
billel madridi 2013년 3월 25일
it's useful your answer, i just added a unit delay and it works thanks
Walter Roberson
Walter Roberson 2014년 3월 15일
편집: Walter Roberson 2017년 5월 6일
Divyasri Venkat commented, "Thanks sir even i got the same error"
Ahmed Badie
Ahmed Badie 2015년 4월 7일
It works, thanks
tahahmady@gmail.com
tahahmady@gmail.com 2015년 7월 13일
thank you , after all this time , its works finally by your answer
Ibrahim Banat
Ibrahim Banat 2016년 2월 17일
where can I add this block in my system?
Azzi Abdelmalek
Azzi Abdelmalek 2016년 2월 17일
just before the feedback
Ibrahim Banat
Ibrahim Banat 2016년 2월 17일
firstly, thanks for reply. but I don't know the exact location to insert the block.. my system consists of 72 cells PV panel and I'm studying the shading effect and the same problem appear every time. Can I send you my system to see whats I mean?
Ibrahim Banat
Ibrahim Banat 2016년 2월 18일
Any help Mr. Azzi Abdelmalek
lukemya fabien
lukemya fabien 2016년 7월 29일
I have the same error but in the PV array block, I don't see where I can place the unity delay. Please help me to solve this problem. Thanks.
Mohamed Yousry
Mohamed Yousry 2017년 5월 6일
Thanks Dear Azzi, this answer surely solved my problem.
Om Krishan
Om Krishan 2018년 11월 1일
Thanks@VAzzi Abdelmalek it works
Praveen Kumar
Praveen Kumar 2018년 11월 7일
Same issue. Where should I place the unit delay? Someone, please comment. Thank you.
Lukas Kretzschmar Waeny
Lukas Kretzschmar Waeny 2019년 3월 12일
Same issue, thanks for helping ...
Sudhanshu  Telrandhe
Sudhanshu Telrandhe 2019년 11월 8일
thanks for helping ...
NING XUE
NING XUE 2020년 3월 10일
Simulink cannot solve the algebraic loop containing 'partial_shading_conditions2/PV_SERIES2/Subsystem/Divide2' at time 0.039814999999999996 using the LineSearch-based algorithm due to one of the following reasons: the model is ill-defined i.e., the system equations do not have a solution; or the nonlinear equation solver failed to converge due to numerical issues. To rule out solver convergence as the cause of this error, either a) switch to TrustRegion-based algorithm using set_param('partial_shading_conditions2','AlgebraicLoopSolver','TrustRegion') b) reducing the VariableStepDiscrete solver RelTol parameter so that the solver takes smaller time steps. If the error persists in spite of the above changes, then the model is likely ill-defined and requires modification.
The same issue,but I have place the unit delay before the feedback,can't solve this problem
can you help me?

댓글을 달려면 로그인하십시오.

추가 답변 (5개)

Kalyani Dhawad
Kalyani Dhawad 2018년 9월 6일

0 개 추천

I have same problem in pv system
Ahmed
Ahmed 2019년 6월 19일

0 개 추천

I've faced the same problem before, it can be solved by adding a unit delay block and type "set_param('trial_3','AlgebraicLoopSolver','LineSearch') " in the command prombit window of MATLAB.

댓글 수: 2

matham kiran kumar
matham kiran kumar 2019년 8월 3일
Thank you. Its working for me too.
Akash maheshwari
Akash maheshwari 2019년 10월 3일
can you pleasse explain set_param('trial_3','AlgebraicLoopSolver','LineSearch'). i did that in my matlab command window but window show me that algebraic loop parameter did not found.

댓글을 달려면 로그인하십시오.

Gert Kruger
Gert Kruger 2019년 6월 27일

0 개 추천

댓글 수: 2

PIRC
PIRC 2019년 12월 2일
same problem. you model not helpful.
Malaiyappan M
Malaiyappan M 2020년 8월 17일
Inductor is not designed properly

댓글을 달려면 로그인하십시오.

ayachi amor
ayachi amor 2021년 6월 14일

0 개 추천

Click on the PV panel itself, go to ' Advanced', then click on 'Break algebaic loop in internal model'.
hope to be solved.

댓글 수: 1

Zachary Naidoo
Zachary Naidoo 2022년 4월 14일
Hi, I have tried this by my displays for voltage and current show nan when for this. However if I don't click it then it displays the result with an error

댓글을 달려면 로그인하십시오.

카테고리

도움말 센터File Exchange에서 Simulink에 대해 자세히 알아보기

제품

질문:

2012년 11월 23일

댓글:

2022년 4월 14일

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by