How to create/ simulate fault in asynchronous machine in simulink?

조회 수: 2 (최근 30일)
elbordj mohamed
elbordj mohamed 2020년 5월 9일
답변: Sabin 2025년 1월 30일
How can I simulate the faults in the asynchronous machine ?ex: broken bar or stator winding.

답변 (1개)

Sabin
Sabin 2025년 1월 30일
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding slot level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point: