Extremely high THD in FFT Toolbox
이전 댓글 표시
I want to calculate THD of the waveform from my three-phase rectifier in Simulink. I am using the FFT toolbox for this, however when I analyse DC voltage and currents of the rectifier. My fundamental frequency is 400Hz, however as seen in the picture, the spectrum does not show this frequency at all. I am also confused about the very high magnitude of harmonic at 0, which I don't understant. I would appreciate your help.

댓글 수: 3
Michael Soskind
2020년 4월 23일
Hi OP,
I would say that the value is most likely off by 2*pi. This is based on your definition of frequency in Hz vs angular frequency in rad/s, and is most likely just a units error.
Best,
Michael
David Goodmanson
2020년 4월 23일
Hi LS,
The large value at zero frequency is because your signal has a large DC offset. If you subtract the mean of the signal from the signal then the DC offset is zero and the somewhat meaningless peak at f=0 goes away.
Marta Grzybek
2020년 4월 23일
편집: Marta Grzybek
2020년 4월 23일
채택된 답변
추가 답변 (0개)
카테고리
도움말 센터 및 File Exchange에서 Spectral Measurements에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!