Simplified Synchronous Machine - Speed Regulation

조회 수: 6 (최근 30일)
Mark Hamill
Mark Hamill 2020년 1월 21일
댓글: John Noon 2020년 1월 23일
I got the desired waveform and tried to adjust the load to 1MW and 500kW together. I got the following waveform
1.PNG
Heres the question. at rotor speed and mechanical torque from 0.2s, why isnt it a straight line like when both loads are 800KW?

채택된 답변

John Noon
John Noon 2020년 1월 21일
This model has a PI speed regulator. What you are seeing at 0.2 seconds is the dynamics of this PI regulator. The regulator is changing the mechanical torque to "regulate" the speed to its original value. As time goes to infinity, these will be a straight line again, but when you introduced the step response in power the torque and speed must regulate. If you search "PI controller step response" you will find similar looking waveforms.
  댓글 수: 4
Mark Hamill
Mark Hamill 2020년 1월 23일
Alright. I understand. 1 last question, what are the initial conditions? Are they the parameters of the generators or others? Thanks
John Noon
John Noon 2020년 1월 23일
The generator has an initial condition, and the PI regulator has an initial condition too. The PI regulator's initial condition is the same as the Tmec block in the model since that is the steady state torque for the condition at the start.