Hi
I was wondering if someone known if I can read in TEDS information from say an accelerometer, so that I don't have to set the sensitivity myself.
I am working with the DAQ toolbox (session-based) and a National Instrument module.
thanks Esben

답변 (1개)

Lars Hansson
Lars Hansson 2023년 4월 6일
Yes, here is a good place to start/function to use:
daq.ni.NIDAQmx.DAQmxGetPhysicalChanTEDSBitStream
  댓글 수: 1
Andrei
Andrei 2025년 5월 15일
Note that this approach is not documented. Please contact MathWorks Technical Support to discuss workaround options.