How PI control tuned using the error information ?

조회 수: 4 (최근 30일)
Bisrat Gezahegn
Bisrat Gezahegn 2019년 5월 13일
편집: Bisrat Gezahegn 2019년 5월 14일
How PI control tunned using the error information
error = refefrence-measure
PI = kp+ki/s
vb =( refefrence-measure ) *(kp+ki/s);
I can access the error excil data, so i need to determone the PI gain. Any information please. thanks

답변 (1개)

Raj
Raj 2019년 5월 14일
I'll assume you have a set of time domain (rise time, settling time, overshoot etc) or frequency domain (gain margin, phase margin etc) criteria that should be met by your closed loop system. Now you have multiple options to estimate and tune your PI gains.
1) Use root locus technique to see the movement of system Poles-Zeros in the S-Domain and pick the gain which meets your desired criteria.
2) Use MATLAB pidTuner. Its a very user friendly tool to tune your controller. Just type 'pidTuner' in your command prompt. Contrary to the name, you have option to choose type of controller (P,PI,PID etc).
Hope this helps. Get back in case you are having any difficulty.
  댓글 수: 3
Raj
Raj 2019년 5월 14일
Ok, so i understand that you dont have the system's transfer function and you are just using it as a black box. In that case i suggest you generate a set of input-output data and use the pidTuner to identify the system first. Then you can proceed with design and tuning of controller.
Untitled.jpg
Bisrat Gezahegn
Bisrat Gezahegn 2019년 5월 14일
편집: Bisrat Gezahegn 2019년 5월 14일
It is clear up to here, I have input data from the output of the PI and and output data from the negative feeedback loop. But, what is procedure to collect these INPUT/OUTPUT data for two or more parrallel PI control ( not cascaded or double loop)? They have influnce each other? Is threre any guiding rules?

댓글을 달려면 로그인하십시오.