I am using Matlab R2011a. I am creating any circuit model in Simulink, and after I simulate, an error log opens saying initialisation commands cannot be evaluated, hw to solve?
조회 수: 1 (최근 30일)
이전 댓글 표시
Some errors I mention as:
Block Error- Error in 'Introduction_to_Simulink/AC Voltage Source': Initialization commands cannot be evaluated.
Error in 'Introduction_to_Simulink/Current Measurement': Initialization commands cannot be evaluated.
Model Error- The diagram must contain a powergui block. The block must be named powergui and should be located at the highest level of your diagram where SimPowerSystems blocks are found.
This problem arises as block error and model error, and its occurring in evry bolck and model, Please give me solution as early as possible
댓글 수: 0
채택된 답변
Ryan G
2012년 8월 13일
편집: John Kelly
2015년 2월 26일
Based on the error it sounds like you are utilizing SimPowerSystems. Those blocks require the powergui to determine the solver. Look at this simple circuit demo to see the powergui in action.
추가 답변 (0개)
참고 항목
카테고리
Help Center 및 File Exchange에서 Sources에 대해 자세히 알아보기
제품
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!