Induction Motor - Motoring mode

Hello everybody !
I have one problem with my simulation. I have an 18,5 kw induction motor in motoring mode , and i need to compare torque with rotor speed for differdent loads.
First , torque is rated torque which is 153,7 [Nm] and rotor speed reached 1200 rmp.
In second example torque is half of rated torque which is 76,8 but on the graphics torque is very high and rotor speed is good. Can someone explain me please?
1.png
2.png

답변 (1개)

Andrey Er
Andrey Er 2019년 6월 3일

0 개 추천

Good day.
It seems ok for me. When no load on motor shaft Rotor Speed = Electrical Speed/P so no Slip
When u apply some torque rotor speed drops proportional Slip.

커뮤니티

더 많은 답변 보기:  Power Electronics Community

카테고리

도움말 센터File Exchange에서 Motor Control Blockset에 대해 자세히 알아보기

제품

릴리스

R2018b

질문:

2019년 3월 27일

답변:

2019년 6월 3일

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!