how to solve this problem

조회 수: 11 (최근 30일)
minglangruye bian
minglangruye bian 2019년 3월 4일
답변: Sabin 2025년 6월 5일
An error occurred while running the simulation and the simulation was terminated
For block 'PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch', control port value '0' is not in between '1' and '6'. To suppress this message and use the default port, you can change the settings of 'Diagnostic for default case' to 'None'
Component: Simulink | Category: Block error
  댓글 수: 2
Walter Roberson
Walter Roberson 2019년 3월 4일
Either figure out why the control port was 0, or else make the change they suggest.
Sai kartheek Chavali
Sai kartheek Chavali 2019년 3월 4일
PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch
what is the model functionality?

댓글을 달려면 로그인하십시오.

답변 (1개)

Sabin
Sabin 2025년 6월 5일
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a multiport switch that is 0 but the parameter 'Data port order' is set to One-based contiguous (this means that the out of range condition is: the control input is less than 1 or greater than the number of data inputs.).