how to get Beta in power transformation ?

조회 수: 2 (최근 30일)
Saif Zahran
Saif Zahran 2019년 3월 3일
답변: Sabin 2025년 1월 13일
I need help
per the diagram, i am designing DQ frame controller for single phase grid connected to H-bridge inverter and LCL filter.
Current Decoupled to alpha which is sine wave, and beta which need to be shiftted by 90 degree.
in above diagram i am using transport delay to shift beta, but this way does not give accurate result.
I need help of any other way to be implemented to get beta with same freauency and amplitude of alpha
Thanks
  댓글 수: 1
JANARDHAN GURRAM
JANARDHAN GURRAM 2019년 12월 20일
I am working in the same environment of producing alpha beta to dq for a single phase inverter . I too started with transportation delay but getting ac outputs in d, q profiles when i watch them .I guess they are needed to be dc components .
Have solved your issue.?
Do you find the solution for the same .
Can u please help me in any way .

댓글을 달려면 로그인하십시오.

답변 (1개)

Sabin
Sabin 2025년 1월 13일
In continuous time, to achieve a 90-degree phase shift, you can use a Transport Delay block (or a Variable Transport Delay). The key is to set the delay time to a quarter of the signal's period. You can use a PLL to get the frequency: