Relation between flux linkage and voltage constant | power_PMSy​nchronousM​achinePara​ms

Hello to everyone,
I am currently working on mathematical modeling of permanent magnet synchronous motor and stuck in computing some variables from standart manufacturer specifications.
Actually, I want to understand how can I compute flux linkage from Back EMF (Ke) constant.
In Simulink, the Permanent Magnet Synchronous Machine block (Simulink Library -> Simscape/Power Systems/Specialized Technology/Fundamental Blocks/Machines), under the Advanced tab, there is a GUI which name is "Compute from standard manufacturer specifications". In this GUI, I am able to understand the math beyond the Voltage constant (ke) transformations between Vpeak/kRPM and Vrms/(rad/s). But I can't understand how the "flux linkage established by magnets (V*s)" is calculating from this voltage constant value.
Unfortunately, there is no information in Help section of this block about this topic.
Can someone please explain this relation by mathematical derivations.
Thanks in advance.
Best Regards,
Yasin

 채택된 답변

Yasin Cetin
Yasin Cetin 2019년 2월 23일
ramesh.PNG
solved, thanks.

댓글 수: 4

seems correct.
Using the above equation and data, where omega M = 1 and 4 pole pairs
flux linkage = sqrt(2)/sqrt(3)*0.03133/(4*1) = 0.0063952
Could you please specify the source for this?
Radek
Radek 2024년 5월 1일
편집: Radek 2024년 5월 1일
Why divide by sqrt(3) if voltage is already stated as rms? And then why multiply by sqrt(2)?

댓글을 달려면 로그인하십시오.

추가 답변 (3개)

armorfid
armorfid 2023년 10월 2일
편집: armorfid 2023년 10월 2일
The exact relationships between voltage constant Ke [V/krpm], torque constant Kt [N·m/A], and flux linkage λpm [V·s] are described on this page: https://www.mathworks.com/help/mcb/ref/surfacemountpmsm.html
These are valid for both surface and interior PMSM.

댓글 수: 2

Why mathworks divides Ke based on peak voltage by sqrt(3) ? That implies RMS regime. But RMS is meanigless in FOC theory.
At least I can exaplin the 2/3 term seems they can be exaplained by from adding https://e2e.ti.com/support/microcontrollers/c2000-microcontrollers-group/c2000/f/c2000-microcontrollers-forum/298101/torque-calculation-and-definition-of-flux-unit-v-hz/1043212#1043212
Also, here mathworks doesn't use sqrt(3) https://www.mathworks.com/help/sps/ug/parameterize-a-permanent-magnet-synchronous-motor.html. But they talk about Voltage peak to ground.
And the voltage between line conductors is 3 times the phase conductor to neutral voltage, so I guess that is what is happening. V_L-L is converted to V_L-N.

댓글을 달려면 로그인하십시오.

Yasin Cetin
Yasin Cetin 2019년 2월 20일
편집: Yasin Cetin 2019년 2월 20일
Hello again,
I found at the bottom of the following link
"As expected, the measured torque and back EMF constants have approximately the same value (0.18) and are related to the permanent magnet flux linkage via the number of pole pairs N of the motor:
flux linkage = (back EMF constant)/(number of pole pairs)"
But, in the GUI which I mentioned above post, results are not satisfying this equation. (0.03133/0.00639521 = 4.899)
Kadir Akgül
Kadir Akgül 2019년 6월 22일
I have same problem. Did you solve the problem?

카테고리

도움말 센터File Exchange에서 Specialized Power Systems에 대해 자세히 알아보기

제품

릴리스

R2018a

질문:

2019년 2월 20일

편집:

2024년 5월 1일

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by