online analysis on background data, ni card analog input

조회 수: 2 (최근 30일)
Ehsan
Ehsan 2019년 1월 14일
편집: Ehsan 2019년 1월 24일
Hi,
I am trying to get access to a global variable that is updated in the listener function of a ''DataAvialable'' event, relating to the startbackground for NI card analog input.
It seems that neigther a global variable nor the "UserData" of the daq session object are not updated before stoping the background recording. Is there any way around this to get online access to a variable that is updated in the listener function while the recording is still running?
Thanks,
Ehsan

답변 (1개)

Kenny Shu
Kenny Shu 2019년 1월 23일
When the session's "UserData" variable is updated in the "DataAvailable" event callback, the result is immediately accessible from the workspace.
By setting up the listener as follows,
s1 = daq.createSession('ni');
s1.addAnalogOutputChannel('Dev1','ao1', 'Voltage');
s2 = daq.createSession('ni');
ch = s2.addAnalogInputChannel('Dev1','ai1', 'Voltage');
ch.TerminalConfig = 'SingleEnded';
s2.DurationInSeconds = 60;
lh = addlistener(s2, 'DataAvailable', @dataAvailableCallback);
s1.queueOutputData(linspace(0,10,30000)');
startBackground(s1)
startBackground(s2)
function dataAvailableCallback(src, event)
src.UserData = [src.UserData; event.Data];
end
you may access the live "UserData" while the acquisition continues in the background:
>> s2.UserData(end)
ans =
9.1314
  댓글 수: 1
Ehsan
Ehsan 2019년 1월 23일
편집: Ehsan 2019년 1월 24일
this doesn't work in the continuous mode.
s2.IsContinunous = true;

댓글을 달려면 로그인하십시오.