How can convert variable-size signal ?
조회 수: 2 (최근 30일)
이전 댓글 표시
Hi, I am getting this error in simulink. can anybody help how can be removed this error ? I only get this error when I attach switch with my ADC block. Also, I have attached the design snap.
The signal at input port 1 of 'ADC_Sign_E_ref_12/Switch2' is a variable-size signal with a nondiscrete sample time. The sample time for any variable-size signal must be discrete.
댓글 수: 4
Walter Roberson
2018년 11월 12일
When a MATLAB Function Block is used, Simulink would tend to assume that the output is variable length. I would not count on the analyzer being able to prove that the output will be scalar: I would recommend configuring the output port.
Also can you post the code so we can see if there is an accidental variable length output path?