Check Valves causing insane pressures

조회 수: 8 (최근 30일)
Andrew
Andrew 2012년 6월 22일
I'm working on a system model that uses a set of 4 check valves to rectify a sinusoidal flow. Right now I am seeing some very strange behavior from the check valves and I'm not sure what's going on. In order to try and eliminate issues I broke the problem down to a very simple model and I'm still seeing issues. Basically when the flow gets reversed pressure readings from before the check valve behind to oscillate between their positive and negative values, basically each consecutive value appears to be the inverse of the previous value. I've linked to my model below. If anyone has and suggestion as to what is happening I would love to hear it.
Thanks, -Andrew
  댓글 수: 1
K E
K E 2012년 6월 22일
If no one gives a specific answer (sorry I can't), it might be worth doing a search for answers by a previous poster named Arnaud Miege who had a background in Simulink hydraulics. He had a lot of good detailed answers and you might turn up something useful in reading through them.

댓글을 달려면 로그인하십시오.

채택된 답변

Rebecca Carter
Rebecca Carter 2012년 7월 2일
Hello,
I tried out your model and found that if I unchecked 'Use fixed-cost runtime consistency iterations' then it worked fine. It also worked, and much faster, if I used the global solver ODE15s.
--Rebecca
  댓글 수: 1
Guy Rouleau
Guy Rouleau 2012년 7월 2일
If you are interested to know why, I recommend going the 3 papers titled "Real-Time Simulation of Physical Systems Using Simscape"

댓글을 달려면 로그인하십시오.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Upgrading Hydraulic Models to Use Isothermal Liquid Blocks에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by