Can I find/see the requirement I linked inside a test sequence that is inside a test harness in Simulink with Matlab script?

조회 수: 1 (최근 30일)
I tried using the line of code below...
sltest.testsequence.readStep([model,'/Test Sequence'],steps{g})
...hoping to catch the linked requirement inside the Test Sequence step. However I only get the struct with the fields:
Name:
Action:
IsWhenStep:
IsWhenSubStep:
Description:
TransitionCount:
Is there a way I could try to see the requirement just through Matlab Script?
  댓글 수: 1
Nikhil Boddula
Nikhil Boddula 2021년 5월 27일
Even I'm trying for the same. Please post line of code how to catch the linked requirement inside the Test Sequence step if you have got resolved.

댓글을 달려면 로그인하십시오.

답변 (1개)

Raymond G. Estrada Jr
Raymond G. Estrada Jr 2023년 2월 10일
Here's how you can do this via existing APIs (using our do178CaseStudyStart demo)
%Block path to test sequence diagram
myTS = 'AHRS_Voter_Harness_HLR_12/Test Sequence';
%extract steps
myTS_steps = sltest.testsequence.findStep("AHRS_Voter_Harness_HLR_12/Test Sequence");
%Get the Stateflow object for the Test Sequence block
tsObj = root.find("-isa", "Stateflow.ReactiveTestingTableChart", "Path", "AHRS_Voter_Harness_HLR_12/Test Sequence");
%Loop through all steps to extract requirement information
for ii=1:length(myTS_steps)
state_step = tsObj.find('-isa', 'Stateflow.State', 'Name', myTS_steps{ii}); %Stateflow object for the step "chart"
outlinks = slreq.outLinks(state_step); %Get outlinks for the step "chart"
dest = arrayfun(@(x) x.destination, outlinks{ii,1}); %Get the destination information
%Example of packaging the data
reqInfo.(myTS_steps{ii}).path = state_step.Path;
reqInfo.(myTS_steps{ii}).stepContent = state_step.LabelString;
reqInfo.(myTS_steps{ii}).reqLinks = dest{ii,1};
end