How to simplify the name of component's ports when importing an ARXML file in SIMULINK?

조회 수: 2 (최근 30일)
When importing a composition or a component from an ARXML file, Simulink uses the following format for port naming: <name_of_port>_<name_of_variable>_<read|write>.
I want to systematically simplify this naming by displaying only <name_of_variable>
How can I configure simulink for this?

채택된 답변

TAB
TAB 2018년 6월 5일
As far as I know, port naming is build-in into AUTOSAR toolbox and can not be configured or changed.
This is more or less becuase of naming convention of AUTOSAR architecture. If you generate a C- template file for your SWC from authoring tool, then generated port APIs are similar name_of_port_<name_of_variable>_<read|write>.
But good thing is, the exact names are required at root level only. We can change the port names at lower hierarchy (for example inside runnable).
In my case, I use scripts to import the arxml. And after the model is created script modifies the port names in lower hierarchy (not at root level) to short names like "name_of_variable". Thses ports with short names are used further for logic implementation.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 AUTOSAR Blockset에 대해 자세히 알아보기

제품


릴리스

R2018a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by