Simscapeの電気素子の物理モデルを使用しようとしたところ
エラー: Capacitance_change2_20180524_mf (line 60) * ['Capacitance_change2_20180524/Capacitor', 'Capacitance_change2_20180524/Controlled Voltage Source2', 'Capacitance_change2_20180524/Current Sensor', 'Capacitance_change2_20180524/Inductor', 'Capacitance_change2_20180524/PS-Simulink Converter', 'Capacitance_change2_20180524/PS-Simulink Converter1', 'Capacitance_change2_20180524/Resistor', 'Capacitance_change2_20180524/Simulink-PS Converter', 'Capacitance_change2_20180524/Voltage Sensor']: Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks: 'Capacitance_change2_20180524/Capacitor' 'Capacitance_change2_20180524/Controlled Voltage Source2' 'Capacitance_change2_20180524/Current Sensor' 'Capacitance_change2_20180524/Inductor' 'Capacitance_change2_20180524/PS-Simulink Converter' 'Capacitance_change2_20180524/PS-Simulink Converter1' 'Capacitance_change2_20180524/Resistor' 'Capacitance_change2_20180524/Simulink-PS Converter' 'Capacitance_change2_20180524/Voltage Sensor'
というエラーが出ます.対応方法が全く分かりません. 教えていただけると幸いです.

답변 (1개)

Hiroumi Mita
Hiroumi Mita 2018년 9월 3일

0 개 추천

次のエラーが気になります。 There is no Solver Configuration block connected to Physical Network with the following blocks:
Solver Configuration blockというBlockが、Simscapeの物理ネットワークには必要です。 必ず一つつけてください。