Re-using image co-registration parameters

조회 수: 1 (최근 30일)
Pawel Tokarczuk
Pawel Tokarczuk 2018년 4월 13일
편집: Matt J 2018년 4월 13일
I have some velocity-encoded MR images (magnitude and phase) which I would like to co-register. The magnitudes are clean, and allow for straightforward prior masking (according to a threshold), but it's the phase images that I really need to align. However, those are noisy and - worse than that - wrapped. How can I can co-register the magnitudes, then re-use the parameters of that transformation to co-register the phases ? The images are acquired simultaneously, so this is a valid thing to do.

채택된 답변

Matt J
Matt J 2018년 4월 13일
편집: Matt J 2018년 4월 13일
Apply imregtform() to the magnitude images to obtain the transformation parameters. Then apply the transformation to the phase images or whatever images you want using imwarp().

추가 답변 (0개)