Inherited Sample time using from workspace
이전 댓글 표시
Hi,
I'm loading some data into simulink ('from workspace' block) from my matlab workspace, the data is in the form of a timeseries with one set of data and one set of Time data.
I use sim( 'model' ) to run the simulation.
The warning I get is
Warning: Source 'envi_NA540204_MGA1/rNA540204/BackToArmFrame_DATA_IN/From
Workspace1' specifies that its sample time (-1) is back-inherited. You should
explicitly specify the sample time of sources. You can disable this diagnostic
by setting the 'Source block specifies -1 sample time' diagnostic to 'none' in
the Sample Time group on the Diagnostics pane of the Configuration Parameters
dialog box.
It was my understanding that I do not need to specify sample time if I use timeseries with Time data, what am I not getting here?
thanks pjf
답변 (1개)
카테고리
도움말 센터 및 File Exchange에서 Sources에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!