Simulink Linear Analysis Pole/Zero Plots

조회 수: 10 (최근 30일)
Andres
Andres 2017년 8월 15일
댓글: Sebastian Castro 2017년 8월 16일
Attached is the Simulink file I'm having problems with. I have this system controlled by a PID controller which gives me the desired response on 'Scope1'. Now I want to do some plots using "Analysis -> Control Design -> Linear Analysis...".
Here I get my bode and step responses plot, but when I go to the "I/O Pole/Zero Map" all the poles and zeros are on the right side (real positive values) which means the system is unstable and it seems to be contradictory from the step and bode plot that shows an stable system. Am I missing or misinterpreting anything? Here are the bode and step plots I get:
And this is the I/O Pole/Zero Map:

채택된 답변

Sebastian Castro
Sebastian Castro 2017년 8월 15일
편집: Sebastian Castro 2017년 8월 15일
Based on the staircase step response, looks like your system is discrete.
This means that stability is inside the unit circle (circle of radius 1), which it is :)
- Sebastian
  댓글 수: 2
Andres
Andres 2017년 8월 15일
Hooo ok, so in discrete systems everything inside the circle is stable? Do you have any resource where I can read about this? Thank you Sebastian :)

댓글을 달려면 로그인하십시오.