In xPC Target, one could define a target with the command
target = xpc('TcpIp',address,port);
As of release 2017a, it seems this has been removed and the
slrt('TargetName')
command is required instead. While this works fine, it requires setting up the target parameters using the GUI interface with the slrtexplr command to be the same for every host and every target. For communication with a number of different target/host pairs, this means manually going through and making sure that the GUI-controlled target definition matches for each pair, which is somewhat cumbersome.
Is there some way to define a target through the script-line interface, like with the xpc command above, instead of using slrtexplr?
댓글 수: 0
채택된 답변
Brian Hannan
2017년 8월 12일
편집: Brian Hannan
2017년 8월 12일
Use
tg = slrt;
tg.TcpIpTargetAddress = '10.10.10.10';
tg.TcpIpTargetPort = '22222';
etc.