simulink add_block fails for 'built-in/Transfer Fcn'
조회 수: 4 (최근 30일)
이전 댓글 표시
simulink add_block fails for 'built-in/Transfer Fcn' is it because of the white space?
댓글 수: 0
답변 (1개)
Swarooph
2017년 6월 28일
Using block names like 'Transfer Fcn' works only if you use the full block path as follows:
add_block('simulink/Continuous/Transfer Fcn', 'untitled/Transfer Fcn')
Otherwise, you can use 'built-in/blocktype' as a source block path name for Simulink built-in blocks, where blocktype is the built-in block type (that is, the value of its BlockType parameter (see Common Block Properties). However, using 'built-in/blocktype' causes some default parameter values of some blocks to be different from the defaults that you get if you added those blocks interactively using Simulink.
add_block('built-in/TransferFcn', 'untitled/Transfer Fcn1')
댓글 수: 0
참고 항목
카테고리
Help Center 및 File Exchange에서 Interactive Model Editing에 대해 자세히 알아보기