How can I change the active variant subsystem before simulation starts?

조회 수: 6 (최근 30일)
Max Bjurling
Max Bjurling 2017년 4월 18일
댓글: Max Bjurling 2017년 4월 27일
I have a model with multiple instances of a variant subsystem. The variant subsystem itself is in a library. How can I choose which variant to use for each instance using a script? Currently I use the PostLoadFcn callback of my top model to set active variant of each instance using set_param(). But if I edit the variant library block (and I do this often), all instances go back to the default variant in my top model. So I need a way to change them back before I run a simulation, and I don't want to have to close and re-open the top model just to do this (invoking the PostLoadFcn callback).
If I use the InitFcn to set the active variant, I get an error that I can't change variant during simulation.

답변 (1개)

Ankit Bhardwaj
Ankit Bhardwaj 2017년 4월 26일
편집: Ankit Bhardwaj 2017년 4월 26일
There can be multiple ways to solve this issue.
1. Create an empty subsystem at the top level with an openFcn callback with the same code which you have in postLoadFcn callback. This will be able to fix the variants in one click.
2. You can also think of using Variant objects in the base workspace to fix this issue.
  댓글 수: 1
Max Bjurling
Max Bjurling 2017년 4월 27일
Thanks Ankit! Opening an empty subsystem at top level is certainly easier than closing and reopening the entire model. But I would like to do it all using scripts, and since my model will be simulated by my colleagues too it's a bit unintuitive to have to open and close an empty subsystem. Could you elaborate a bit more on your second suggestion?

댓글을 달려면 로그인하십시오.