PMSM motor controller model, rotor angle output conversion for Park transform
이전 댓글 표시
..
Hi,
I am developing a PMSM motor controller model in Simulink, I have the PMSM motor from Simpower systems, it gives the motor rotor angle in radians but when I convert it to electrical angle by multiplying by 3 for the number of pole pairs and give it to Clark and park transforms model, the results are not consistent. It gives a linear ramp, I am not sure how to interpret that, I want the conversion so that the park transform and inverse Park transform will work correctly.
Regards,
CB
채택된 답변
추가 답변 (1개)
Sabin
2023년 1월 9일
0 개 추천
Rotor angle can be seen as a linear ramp when rotor speed is constant. When using it in Park transform the result should be the same as when we reset the angle every 2*pi radians because we need the sin/cos(theta). I suspect the initial angle might be the root cause of mismatch or different axis definition (a-phase aligned with the d or q axis).
커뮤니티
더 많은 답변 보기: Power Electronics Community
카테고리
도움말 센터 및 File Exchange에서 Permanent Magnet에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!