Simscape full-wave bridge rectifier demo simulation time

조회 수: 10 (최근 30일)
ice_man
ice_man 2011년 3월 14일
Hi,
Can anybody suggest why this demo only outputs a signal during the last 1.9 seconds of its simulation?
Regards,

채택된 답변

Arnaud Miege
Arnaud Miege 2011년 3월 14일
Are you talking of ssc_bridge_rectifier.mdl? If so, the stop time is set to 0.05s. Where do you get the 1.9s from?
I assume you must have changed the stop time to something greater than 2s and that you're looking at the scope. On the scope, click on the Scope parameters button (next to the printer one), go to the "Data history" tab and untick "Limit data points to last: 5000".
This is the default setting of the scope (to limit how much memory is used), so it will only plot the last 5000 data points, which happen to correspond to about 1.9s worth of simulation.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Converters (High Power)에 대해 자세히 알아보기

제품

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!