필터 지우기
필터 지우기

Builing a Shunt active power filter in the synchronous reference frame

조회 수: 2 (최근 30일)
KADEM Mohamed
KADEM Mohamed 2016년 4월 21일
답변: abdelkader yousfi 2016년 7월 21일
This schema representing a shunt active power filter in the synchronous reference frame, I'm focusing on the Area in the red box !
I want to learn how to build my own shunt active power filter in the synchronous reference frame from scratch, i understood pretty much the method behind it, but i am stack within Simulink, i followed the steps of the Algorithm one by one :
  1. Get the load's current (scope : I_Load)
  2. Clark Tranforation (scope : ab_Frame)
  3. PLL Gives the SinW/CosW (scope : PLL)
  4. Park transformation (scope : dq_Frame)
  5. Extraction of the Harmonics currents (i*d & i*q)
  6. Back from dq_Frame to ab_Frame (Park Inv)
  7. Back from ab_Frame to abc_Frame (Clark Inv)
My Simulink Model :
I'm stack at step 5 (The blue box) Now that i have I_load in the dq frame,
How can i extract the compensation current i*d and i*q from iq_Load and id_Load ?
what is the simplest way to do that ? (in the schema up, they use an FTJ (the Orange box), what is that ? some also put LPF ( at 2*pi*50) why ?) .
.
.
SCOPE OF THE CURRENT I_Load :

답변 (1개)

abdelkader yousfi
abdelkader yousfi 2016년 7월 21일
thank you I need MATLAB file about you "Builing a Shunt active power filter in the synchronous reference frame"

카테고리

Help CenterFile Exchange에서 Circuits and Systems에 대해 자세히 알아보기

제품

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!