can anybody explain why type 2 FIR filter cannot be used to design high pass filter?
답변 (1개)
Honglei Chen
2016년 1월 14일
0 개 추천
This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.
댓글 수: 2
pavan sunder
2016년 1월 14일
Honglei Chen
2016년 1월 14일
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH