why type 2 FIR filter cannot be used to design high pass filter?
조회 수: 5 (최근 30일)
이전 댓글 표시
can anybody explain why type 2 FIR filter cannot be used to design high pass filter?
댓글 수: 0
답변 (1개)
Honglei Chen
2016년 1월 14일
This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.
댓글 수: 2
Honglei Chen
2016년 1월 14일
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH
참고 항목
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!