필터 지우기
필터 지우기

Simulink space vector PWM simulation

조회 수: 3 (최근 30일)
chen dunzhi
chen dunzhi 2015년 8월 29일
편집: chen dunzhi 2015년 9월 1일
  • The model:
  • Here is what i intend to do.
  1. Generate three phase voltage
  2. Do a alpha beta transformation
  3. Do a Cartesian to Polar transformation
  4. Check the angle output
  5. Since the three phase vector rotates counter-clock wise, I am supposed to get sequence of angle moving from zero to 180 degrees and drops to -180(in no time!) and moves up and repeats itself.But result is that the angle sometimes reaches 172 degrees and turns around,not reaching 180 degrees.Waht is wrong? help!
  • Here is the result

채택된 답변

MUHAMMED FASIL
MUHAMMED FASIL 2015년 8월 31일
Please resubmit ur valid mdl file or send me at tpfasil2007@gmail.com
  댓글 수: 1
chen dunzhi
chen dunzhi 2015년 9월 1일
편집: chen dunzhi 2015년 9월 1일
Thank you. The problem is solved.
The time step for simulation is not small enough, leading to insufficient accuracy.
And I changed the time step from 0.01 to 0.00002 and the result is just as expected.
Thank you again!

댓글을 달려면 로그인하십시오.

추가 답변 (1개)

MUHAMMED FASIL
MUHAMMED FASIL 2015년 8월 30일
Try with abc-AlphaBeta simulink block. Or submit ur mdl file
  댓글 수: 1
chen dunzhi
chen dunzhi 2015년 8월 31일
편집: chen dunzhi 2015년 8월 31일
The mdl file is there named reference_generation.mdl And i checked with abc-AlphaBeta block the result is the same. Does it have anything to do with the solver that Simulink uses? Because there is a warning:

댓글을 달려면 로그인하십시오.