Model Perfectly conducting fluid pipe simscape
이전 댓글 표시
Hi Everyone,
Im trying to model a cooling system in Simscape. From some experimental data I want to input a heat load of 4 kW, and at some other point I want to have a radiator with a cooling rate of 611 W / Kelvin, with an outside temperature of 50 degrees (meaning if the fluid is 50 degs nothing happens, and if it is 60 degrees, It cools with 10*611 W). How best to model this? Im using pipes at the moment with a controlled heat flow rate source for the heat source, and a pipe with a convective heat transfer block for the cooler. The stabilization temperature seems to vary if I change the pipe length, surface area etc which makes sense, but I just want the pipe to just have a ideal conduction if you know what I mean.
I know something is wrong since it does not match the experimental data, even though the values are derived from it.
채택된 답변
추가 답변 (1개)
Yifeng Tang
2025년 10월 28일
1 개 추천
Use a Constant Volume Chamber of represent to coolant volume in your radiator. Connect a thermal resistance block to the H port and set the resistance value to 1/611 [K/W]. I believe that's all you need.
카테고리
도움말 센터 및 File Exchange에서 Sources에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!